The aim of this study was to evaluate the clincal value of multi-slice spiral computed tomography (MSCT) in the diagnosis of double aortic arch (DAA) and analyze the associated angiography and 3D reconstruction imaging to increase the accuracy of DAA diagnosis. Clinical and imaging data from 15 patients diagnosed with DAA by MSCT were summarized and compared with the corresponding surgical observations. The DAA diagnosis by MSCT for the 15 patients was confirmed by the surgical observations. A total of 13 cases were categorized as type I (double arches are open), including nine with a larger right arch, two with a larger left arch and two with balanced arches. Two cases were categorized as type II (one atretic arch), characterized by left atretic arch. Among the 15 patients, ultrasound diagnosis succeeded in nine cases and failed in the rest. A single malformation was identified in only two cases, whereas the rest had single or multiple combination(s) of intracardiac and extracardiac malformations, including seven with different levels of tracheobronchial stenosis. MSCT was demonstrated to precisely diagnose DAA complicated by malformation and tracheobronchial stenosis. MSCT is an essential therapeutic strategy and serves as a primary method in DAA diagnosis.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Application of 64-slice spiral computed tomography angiography in a follow-up evaluation after coronary stent implantation: A Chinese clinical study

Background: This study assessed the application value of 64-slice spiral computed tomography angiography (CTA) in a follow-up evaluation of patients receiving coronary stent implantation. Materials and Methods: A total of 468 patients who underwent percutaneous coronary intervention (PCI) at our hospital between January 2013 and October 2016 were selected for this study. Coronary angiography an...

متن کامل

Three Cases of a Rare Association: Double Aortic Arch

Background Vascular ring is less than 1% of congenital heart disease. Double aortic arch (DAA) is the most common form of it.  Its detecting is important because of the effects of pressure on the esophagus and trachea. Case Report In this study, three children suffering from double aortic arch with symptoms of dysphagia and recurrent aspiration, which in two cases had led to cardiac arrest, wer...

متن کامل

Stridor in a Newborn with Double Aortic Arch-A Case Report

Introduction: Double aortic arch (DAA) is a congenital anomaly of the aortic arch. It is the most common type of complete vascular ring. When it occurs, the connected segment of the aortic arch and its branches encircle the trachea and esophagus, leading to symptoms related to these two structures. Case Report: We present a case of a newborn baby who developed biphasic stridor immediately after...

متن کامل

Aortic Coarctation: Evaluation with Computed Tomography Angiography in Pediatric Patients

Background: Aortic coarctation is a congenital narrowing of the aorta. Computed tomography angiography is used to detect aortic coarctation and determine its extent and severity. Objective: To assess pediatric aortic coarctation by computed tomography (CT) angiography. Material and Methods: This study included eighteen patients (10 males and 8 females) who were clinically diagnosed to have coar...

متن کامل

Methods to evaluate the performance of kilovoltage cone-beam computed tomography in the three-dimensional reconstruction space

Background: Cone-beam computed tomography (CBCT) scanners for image-guided radiotherapy are in clinical use today, but there has been no consensus on uniform acceptance to verify the CBCT image quality yet. The present work proposed new methods to fully evaluate the performance of CBCT in its three-dimensional (3D) reconstruction space. Materials and Methods: Compared to the traditional methods...