Biomechanical parameters of the cornea measured with the Ocular Response Analyzer in normal eyes
نویسندگان
چکیده
BACKGROUND To evaluate the relationships between Reichert Ocular Response Analyzer (ORA) parameters corneal hysteresis (CH) and corneal response factor (CRF) and ocular dimensions, age and intraocular pressure. METHODS Two hundred and twelve eyes of 212 participants with no ocular pathology had CH and CRF measured with the ORA. Intraocular pressure (IOP) was measured with the Dynamic Contour tonometer and central corneal thickness (CCT) was also evaluated. Partial least squares linear regression (PLSLR) analyses were performed to examine the relationships between each response variable, CH and CRF, and the predictor variables age, corneal curvature (CC), axial length (AL), CCT and IOP. RESULTS CH was positively associated with CCT and negatively associated with age (scaled coefficients: CCT 0.62, p < 0.0001; age -0.55, p <0.0001; r2 = 0.25). CRF was positively associated with CCT and DCT IOP and negatively associated with age and AL (scaled coefficients: CCT 0.89, p < 0.0001; DCT IOP 0.46, p < 0.01; age - 0.60, p < 0.0001; AL -0.37, p < 0.01; r2 = 0.43). There was no significant association between CC and CH or CRF. CONCLUSIONS The study suggests that age and CCT are strongly associated with CH and CRF, and that the latter is also influenced by AL and IOP. However, the variables studied could explain only 25% and 43% of the measured variation in CH and CRF, respectively, suggesting other factors also affect the values of these measurements.
منابع مشابه
ویژگیهای بیومکانیکی قرنیه در بیماران مبتلا به کراتوکونوس و ارتباط آن با شدت بیماری
Background and Objective: Keratoconus is a disorder in cornea characterized by constant thinning and prominence that can result in vision defect. Due to ultrasonic changes in the corneal structure caused by keratoconus disease, its rigidity and biomechanical properties are subject to some changes. In this regard, the present study was conducted to determine the correlation of biomechanical feat...
متن کاملIntraocular Pressure Measurements by Three Different Tonometers in Children with Aphakic Glaucoma and a Thick Cornea
Background: To evaluate the agreement in intraocular pressure (IOP) measurements by Ocular Response Analyzer (ORA) and Tono-Pen XL (TXL) with the Goldmann Applanation Tonometer (GAT) and to examine corneal biomechanical properties in aphakic glaucoma patients with a central corneal thickness (CCT) >600 µ. Methods: Thirty-six eyes of aphakic glaucoma patients (group 1) and 40 eyes of normal chil...
متن کاملCorneal biomechanical parameters and intraocular pressure: the effect of topical anesthesia
BACKGROUND The intraocular pressures and biomechanical parameters measured by the ocular response analyzer make the analyzer a useful tool for the diagnosis and management of anterior segment disease. This observational study was designed to investigate the effect of topical anesthesia on the parameters measured by the ocular response analyzer: corneal hysteresis, corneal resistance factor, Gol...
متن کاملHigh intercorneal symmetry in corneal biomechanical metrics
BACKGROUD To evaluate the symmetry of corneal biomechanical metrics, measured using an ocular response analyzer (ORA) and self-built corneal inflation test platform, in bilateral rabbit corneas and to investigate their relationship with physical intraocular pressure (IOPp). METHODS Twenty fresh enucleated eyes from ten rabbits were used for ex vivo whole ocular globe inflation. IOP was increa...
متن کاملOcular Response Analyzer
Until recently, corneal biomechanical properties could not be measured in vivo. The ocular response analyzer is a new, noninvasive device that analyses corneal biomechanical properties simply and rapidly. The ORA allows cornea compensated IOP measurements and can estimate corneal hysteresis (CH) and corneal resistance factor (CRF). It is designed to improve the accuracy of IOP measurement by us...
متن کامل