Amperometric sensing of hydrogen peroxide vapor for security screening
نویسندگان
چکیده
Rapid detection of the hydrogen peroxide precursor of peroxide explosives is required in numerous security screening applications. We describe a highly sensitive and selective amperometric detection of hydrogen peroxide vapor at an agarose-coated Prussian-blue (PB) modified thick-film carbon transducer. The sensor responds rapidly and reversibly to dynamic changes in the level of the peroxide vapor, with no apparent carry over and with a detection limit of 6 ppbv. The remarkable selectivity of the PB-based screen-printed electrode towards hydrogen peroxide leads to effective discrimination against common beverage samples. For example, blind tests have demonstrated the ability to selectively and non-invasively identify concealed hydrogen peroxide in drinking cups and bottles. The attractive performance of the new microfabricated PB-based amperometric peroxide vapor sensor indicates great potential for addressing a wide range of security screening and surveillance applications.
منابع مشابه
AMPEROMETRIC MICROBIOSENSOR FOR THE DETERMINATION OF CHOLINE
The construction and performance of an amperometric microbiosensor for the determination of choline chloride by immobilizing choline oxidase on a cellulose acetate membrane are described. The procedure of choline determination involved the electrochemical detection of enzymatically generated hydrogen peroxide. This microsensor has a linear response between 0.038-0.1 mM choline chloride. The...
متن کاملPaper-based vapor detection of hydrogen peroxide: colorimetric sensing with tunable interface.
Vapor detection of hydrogen peroxide still remains challenging for conventional sensing techniques, though such vapor detection implies important applications in various practical areas, including locating IEDs. We report herein a new colorimetric sensor system that can detect hydrogen peroxide vapor down to parts per billion level. The sensory materials are based on the cellulose microfibril n...
متن کاملFiber Optic Sensors for Hydrogen Peroxide Vapor Measurement
This paper reports on the response of a fiber-optic sensing probe to small concentrations of hydrogen peroxide (H2O2) vapor at room temperature. H2O2 has extensive applications in industrial and medical environments. Conversely, H2O2 can be a health hazard by itself. For example, H2O2 induces cellular damage in human cells and its presence can be used to diagnose illnesses such as asthma and hu...
متن کاملRole of Peroxidase in Clinical Assays: A Short Review
Development of sensitive enzymatic methods for hydrogen peroxide is key for the quantification of several bioconstituents such as glucose, triglycerides, creatinine, and uric acid and so on. Hydrogen peroxide released by the oxidase enzymes are quantified by peroxidase enzyme involving spectrophotometry, fluorimetry, chemiluminisence, potentiometric sensing, amperometric, coulometric and such o...
متن کاملElectrochemical biosensor of nanocube-augmented carbon nanotube networks.
Networks of single-walled carbon nanotubes (SWCNTs) decorated with Au-coated Pd (Au/Pd) nanocubes are employed as electrochemical biosensors that exhibit excellent sensitivity (2.6 mA mM(-1) cm(-2)) and a low estimated detection limit (2.3 nM) at a signal-to-noise ratio of 3 (S/N = 3) in the amperometric sensing of hydrogen peroxide. Biofunctionalization of the Au/Pd nanocube-SWCNT biosensor is...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical and Bioanalytical Chemistry
دوره 395 شماره
صفحات -
تاریخ انتشار 2009