Topographic paracentral corneal thickness with pentacam and orbscan: effect of acoustic factor.
نویسندگان
چکیده
PURPOSE To evaluate the effect of an acoustic factor (AF) on the comparison of central corneal thickness (CCT) and peripheral corneal thickness (PCT) measurements with Orbscan II and Pentacam. METHODS The CCT and PCT at 1, 2, and 3 radial distances from the corneal apex were measured using Orbscan II and Pentacam in 22 right eyes of 22 healthy adults (7 men, 15 women). Three measures were obtained from each 1 of the 25 points measured and then compared to gauge the agreement between both devices at the corneal center and anular areas located at 1-, 2-, and 3-mm distances from the central measurement. Orbscan II readings were considered with and without an AF correction. RESULTS Pentacam provides statistically significant higher values than Orbscan II does at all the 25 locations analyzed (P<0.001). With a few exceptions, the average difference was fairly constant between 20 and 40 μm for all the corneal locations. A high correlation existed between central readings (r(2)=0.927; P<0.001) and average thickness at each one of the annular areas being analyzed (r(2)=0.897 at 1 mm, r(2)=0.876 at 2 mm, and r(2)=0.870 at 3 mm); Pentacam minus Orbscan II value averaged for all the points changed from -28±10 to -22±9 μm after the removal of the AF in Orbscan II. CONCLUSIONS Central and peripheral measurements of the corneal thickness obtained with Orbscan II and Pentacam are significantly different. The removal of the AF in Orbscan II renders lower mean differences but decreases the agreement between both systems and potentially induces an overestimation of CCT and PCT by Orbsan II compared with Pentacam.
منابع مشابه
Central Corneal Thickness Measurement Using Ultrasonic Pachymetry, Rotating Scheimpflug Camera, and Scanning-slit Topography Exclusively in Thin Non-keratoconic Corneas
PURPOSE To evaluate the agreement among Pentacam, Orbscan and ultrasound (US) pachymetry for measurement of central corneal thickness (CCT) in thin corneas with normal topographic pattern. METHODS We included 88 eyes of 44 refractive surgery candidates with thinnest pachymetric readings of 500 micrometers (μm) or less on Orbscan, a normal topographic pattern, no sign of keratoconus, and best ...
متن کاملComparison of Central Corneal Thickness Measured through Pentacam, OCTCasia2, and Orbscan IIz in Normal Individuals
Purpose: To compare the central corneal thickness measured through Pentacam, OCTCasia2, and Orbscan IIz in normal individuals. Methods: In this cross sectional comparative study, the researcher investigated the eyes of 70 normal candidates (140 eyes) with the mean age of 31.42 ± 7.70, referring to Dr. Sedaghat eye clinic for refractive surgery. For each person, Central Corneal Thickness (CCT) w...
متن کاملCentral corneal thickness measurements using Orbscan II, Visante, ultrasound, and Pentacam pachymetry after laser in situ keratomileusis for myopia.
PURPOSE To compare corneal pachymetry assessment using 4 measurement methods in eyes after laser in situ keratomileusis (LASIK) for myopia. SETTING Department of Ophthalmology & Visual Sciences, The Chinese University of Hong Kong, Hong Kong Eye Hospital, Hong Kong SAR. METHODS Fifty-two consecutive patients (103 eyes) who had LASIK for the correction of myopia had Orbscan II (Bausch & Lomb...
متن کاملCentral Corneal Thickness in Highly Myopic Eyes: Inter-device Agreement of Ultrasonic Pachymetry, Pentacam and Orbscan II Before and After Photorefractive Keratectomy
PURPOSE To determine inter-device agreement for central corneal thickness (CCT) measurement among ultrasound pachymetry, rotating Scheimpflug imaging (Pentacam, Oculus, Wetzlar, Germany), and scanning slit corneal topography (Orbscan II, Bausch & Lomb, Rochester, NY, USA) in highly myopic eyes before and after photorefractive keratectomy (PRK). METHODS This prospective comparative study inclu...
متن کاملCorneal thickness measurements with Scheimpflug and slit scanning imaging techniques in keratoconus
PURPOSE To determine the repeatability of corneal thickness measurements with Scheimpflug (Pentacam) and slit scanning (Orbscan) imaging techniques in different grades of keratoconus. METHODS This study was conducted as a cross-sectional research. Imaging with Orbscan and Pentacam was performed on patients with different grades of keratoconus. With each device, 3 measurements were taken at 10...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Eye & contact lens
دوره 37 6 شماره
صفحات -
تاریخ انتشار 2011