Dosimetric comparison of CyberKnife with other radiosurgical modalities for an ellipsoidal target.
نویسندگان
چکیده
OBJECTIVE To compare treatment plans obtained with the CyberKnife (CK) (Accuray, Inc., Sunnyvale, CA) with those of other commonly used radiosurgical modalities, such as the gamma knife (GK), linear accelerator multiple arcs, conformally shaped static fields, and intensity-modulated radiotherapy (IMRT). METHODS An ellipsoidal simulated target was chosen centrally located in a three-dimensional model of a patient's head acquired with magnetic resonance or computed tomographic imaging. It was 25 mm in diameter and 35 mm long. The aims of treatment plans were 100% target volume coverage with an appropriate isodose line, minimum radiation dose to normal tissue, and clinically acceptable delivery. These plans were evaluated by use of a dose-volume histogram and other commonly used radiosurgical parameters such as target coverage, homogeneity index, and conformity index. RESULTS All selected treatment modalities were equivalent in providing full target coverage. For dose homogeneity, all modalities except for multiple isocenter plans for GK (homogeneity index, 2.0) were similar (homogeneity index, congruent with 1.25). Dose conformity was essentially equivalent for all treatment plans except for IMRT, which had a slightly higher value (conformity index, congruent with 1.27). There was a substantial variation in the radiation dose to normal tissue between the studied modalities, particularly at the lower dose levels. CONCLUSION CK plans seemed to be more flexible for a given target size and shape. For a target of limited volume and essentially of any shape, one could obtain similarly good conformal dosimetry with CK and GK. For a regular-shaped but other than spherical target, homogeneous dose distribution could be obtained with all selected modalities except for multiple isocenters, linear accelerator multiple arcs, or GK. Both IMRT and conformally shaped static fields offered good alternative treatment modalities to CK, GK, or linear accelerator multiple arc radiosurgery, with slightly inferior dosimetry in conformity (IMRT).
منابع مشابه
Assessment of basic physical and dosimetric parameters of synthetic single-crystal diamond detector and its use in Leksell Gamma Knife and CyberKnife small radiosurgical fields
Background: To determine the basic physical and dosimetric properties of a new synthetic single-crystal diamond detector and its application for relative small field dosimetry. Materials and Methods: The pre-irradiation dose required to stabilize detector response, dose rate dependence, photon and electron energy dependence, temperature dependence and angular dependence of MicroDiamond detector...
متن کاملA dosimetric comparison of stereotactic body radiation therapy techniques for lung cancer: robotic versus conventional linac‐based systems
The aim of this study is to compare the dosimetric characteristics of robotic and conventional linac-based SBRT techniques for lung cancer, and to provide planning guidance for each modality. Eight patients who received linac-based SBRT were retrospectively included in this study. A dose of 60 Gy given in three fractions was prescribed to each target. The Synchrony Respiratory Tracking System a...
متن کاملMeasurements of the relative output factors for CyberKnife collimators.
OBJECTIVE To determine accurately the relative output factors, defined as the ratio of the nominal dose rate for a given collimator to that of the 60-mm collimator. This is particularly important for radiosurgical treatment of functional disorders, such as trigeminal neuralgia, in which a single large radiation dose is delivered to the target with a small collimator, such as the 5-mm collimator...
متن کاملCyberknife Radiosurgery – A New Treatment Method for Image-guided, Robotic, High-precision Radiosurgery
Cyberknife Radiosurgery – Overview Cyberknife technology is based on radiosurgical principles that have been in clinical practice for 30 years. Radiosurgery is the precise application of a high (tumour-destructing) dose of radiation in a precisely defined target volume, while protecting the surrounding healthy tissue. During radiosurgery, many radiation beams from different directions intersect...
متن کاملDosimetric Comparison of Stereotactic Body Radiotherapy and Intensity-Modulated Radiotherapy to Deliver Hypofractionated Radiotherapy in Organ-Confined Prostate Cancer
We compared the dose conformity, homogeneity, dose to organs at risk, and remaining volume at risk of two radiotherapy techniques --stereotactic body radiotherapy and intensity-modulated radiotherapy (IMRT) to deliver hypofractionated radiotherapy in organ-confined prostate cancer. Eleven successive patients treated on the CyberKnife stereotactic robotic radiosurgical system were taken up for t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Neurosurgery
دوره 53 5 شماره
صفحات -
تاریخ انتشار 2003