Optimization of the 3 m TGM beamline, at CAMD, for constant initial state spectroscopy

نویسندگان

  • Yaroslav B. Losovyj
  • Ihor Ketsman
  • Eizi Morikawa
  • Zhenjun Wang
  • Jinke Tang
  • Peter A. Dowben
چکیده

The 3 m toroidal grating monochromator (TGM) VUV beamline at CAMD/LSU was realigned to achieve better illumination of the monochromator gratings with the goal of substantially increasing the fl ux at the higher photon energies. This is partly accomplished through a tilting of the monochromator (by about of 13.5°), with respect to the plane defi ned by the synchrotron, providing a smaller grazing angle at the initial mirrors. The improved performance of the beamline permits resonant photoemission studies at Gd 4d core threshold without resorting to second order light, which we demonstrate for Gd doped HfO2.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High-throughput Toroidal Grating Beamline for Photoelectron Spectroscopy at CAMD.

A 5 meter toroidal grating (5m-TGM) beamline has been commissioned to deliver 28 mrad of bending magnet radiation to an ultrahigh vacuum endstation chamber to facilitate angle resolved photoelectron spectroscopy. The 5m-TGM beamline is equipped with Au-coated gratings with 300, 600 and 1200 lines/mm providing monochromatized synchrotron radiation in the energy ranges 25-70 eV, 50-120 eV and 100...

متن کامل

High Resolution Photoemission of Organic Systems at 3m NIM Beamline at CAMD

The 3m NIM VUV beamline at CAMD was designed for novel high resolution photoemission experiments. Both solid state samples and gas phase resolution tests demonstrate that high resolution photoemission is possible below 10 meV, and vibronic fine structure in the photoemission final state can be observed: the first direct experimental identification of symmetry dependence in electron-phonon coupl...

متن کامل

Electronic structure of FeAl(1 1 0) using upgraded 6m-TGM at CAMD

A new endstation has recently been commissioned at 6-m toroidal grating monochromator beamline to perform high-resolution photoemission studies in the photon energy range of 10–180 eV. The new endstation is equipped with Phoibos-150 analyzer with a channelplate and charge coupled device (CCD) camera readout to measure the kinetic energy of the electron and its emission angle simultaneously. The...

متن کامل

The Development of the GCPCC Protein Crystallography Beamline at CAMD

The Gulf Coast Protein Crystallography Consortium (GCPCC) is developing a beamline at the LSU/CAMD synchrotron. This beamline will be capable of standard macromolecular multiple-wavelength anomalous diffraction (MAD) phasing experiments over an energy range of 7-17.5 keV. The optical configuration uses a vertical collimating mirror, a channel-cut Si (111) monochromator and a focusing toroidal m...

متن کامل

Upgraded varied-line-space PGM beamline at CAMD

The Center for Advanced Microstructures and Devices’(CAMD) aging plane-grating soft x-ray monochromator beamline was upgraded to a varied-line-space plane-grating monochromator (VLSPGM) beamline. Preliminary measurements indicate significant performance improvements in both the resolving power and the throughput over its predecessor. However, it was found that the VLSPGM has less than the calcu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017