Transmural variation in autoregulation of right ventricular blood flow.

نویسندگان

  • S Yonekura
  • N Watanabe
  • H F Downey
چکیده

We examined transmurally the right coronary autoregulatory flow response to varied perfusion pressures in 11 anesthetized, open-chest dogs. Right coronary artery flow was measured electromagnetically, and its transmural distribution was defined with 15-micron radioactive microspheres. Heart rate, mean aortic blood pressure, right ventricular systolic pressure, end-diastolic pressure, and dP/dtmax were constant. At 100 mm Hg, subepicardial flow averaged 0.48 +/- 0.04 ml/min/g, and subendocardial flow averaged 0.56 +/- 0.05 ml/min/g. In contrast to the left coronary circulation, right coronary hypotension did not cause preferential subendocardial ischemia. As right coronary perfusion pressure was decreased from 100 to 40 mm Hg in five dogs, subepicardial and subendocardial flows were reduced similarly by 35-36%. As right coronary perfusion pressure was elevated from 100 to 150 mm Hg in six dogs, right ventricular subepicardial blood flow increased by 31%, whereas subendocardial blood flow increased by 70%. Right ventricular subendocardial-to-subepicardial flow ratios averaged 1.15-1.20 for perfusion pressures of 40 to 120 mm Hg, and they increased to 1.36 +/- 0.05 at 150 mm Hg. Right coronary artery autoregulatory closed-loop gain averaged 0.47 +/- 0.06 between 70 and 100 mm Hg and was greater than zero from 40 to 120 mm Hg. Between 120 and 150 mm Hg, gain fell to -0.15 +/- 0.10. Regional gain varied from 0.59 +/- 0.10 to 0.44 +/- 0.08 in subepicardium as pressure was decreased from 100 to 40 mm Hg. Subendocardial gains were similar to subepicardial gains over this pressure range.(ABSTRACT TRUNCATED AT 250 WORDS)

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The role of autoregulation and tissue diastolic pressures in the transmural distribution of left ventricular blood flow in anesthetized dogs.

To investigate how autoregulation affects transmural myocardial blood flow, we studied 21 open-chest dogs and varied coronary arterial pressure independently of left ventricular pressure. Total left ventricular myocardial blood flow (FLV) and subendocardiaksubepicardial blood flow ratio (I:O) were measured with microspheres, 9 /an in diameter, injected during autoregulation or maximal coronary ...

متن کامل

Comparison of left and right ventricular blood flow responses during arterial pressure reduction in the autonomically blocked dog: evidence for right ventricular autoregulation.

The effect of reducing systemic arterial pressure with an arteriovenous fistula on left and right ventricular myocardial blood flow was studied in 17 anaesthetised, open chest, autonomically blocked dogs. Global and regional myocardial blood flows were measured with radioactive microspheres. As mean arterial pressure was reduced from 133 mmHg to 78 mmHg left ventricular myocardial blood flow an...

متن کامل

Transmural variation in autoregulation of coronary blood flow in hyperperfused canine myocardium.

We assessed transmurally the coronary autoregulatory response to elevated perfusion pressure in 85 anesthetized, open-chest dogs. Steady state and transient flow distributions were measured with 9 ± 1 /im radioactive microspheres. Steady state distributions of myocardial blood flow were uniform transmurally (P > 0.05) at perfusion pressures of 103 ± 1 (n = 81) and 146 ± 2 (n = 34) mm Hg, wherea...

متن کامل

Transmural right ventricular myocardial blood flow during systole in the awake dog.

This study was designed to quantify and compare transmural myocardial blood flow in the right and left ventricles of awake dogs during systole and diastole, and during total coronary artery occlusion. Studies were performed in six awake dogs chronically prepared with electromagnetic flowmeters and pneumatic occluders on the left circumflex and right coronary arteries. Intermittent coronary perf...

متن کامل

Autoregulation of Blood Flow: Vessel Diameter Changes in Response to Different Temperatures

Background: Autoregulation of blood flow is a marvelous phenomenon balanc- ing blood supply and tissue demand. Although many chemically-based explanations for this phenomenon have been proposed and some of them are commonly used today, biomechanical aspects of this phenomenon was neglected. The biomechanical aspect provides insights to us to model vessel diameter changes more precisely and comp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation research

دوره 62 4  شماره 

صفحات  -

تاریخ انتشار 1988