How Local Annular Force and Collagen Density Govern Mitral Annuloplasty Ring Dehiscence Risk.
نویسندگان
چکیده
BACKGROUND Annuloplasty ring dehiscence is a well described mode of mitral valve repair failure. Defining the mechanisms underlying dehiscence may facilitate its prevention. METHODS Factors that govern suture dehiscence were examined with an ovine model. After undersized ring annuloplasty in live animals (n = 5), cyclic force (FC) that acts on sutures during cardiac contraction was measured with custom transducers. FC was measured at ten suture positions, throughout cardiac cycles with peak left ventricular pressure (LVPmax) of 100, 125, and 150 mm Hg. Suture pullout testing was conducted on explanted mitral annuli (n = 12) to determine suture holding strength at each position. Finally, relative collagen density differences at suture sites around the annulus were assessed by two-photon excitation fluoroscopy. RESULTS Anterior FC exceeded posterior FC at each LVPmax (eg, 2.8 ± 1.3 N versus 1.8 ± 1.2 N at LVPmax = 125 mm Hg, p < 0.01). Anterior holding strength exceeded posterior holding strength (6.4 ± 3.6 N versus 3.9 ± 1.6 N, p < 0.0001). On the basis of FC at LVPmax of 150 mm Hg, margin of safety before suture pullout was vastly higher between the trigones (exclusive) versus elsewhere (4.8 ± 0.9 N versus 1.9 ± 0.5 N, p < 0.001). Margin of safety exhibited strong correlation to collagen density (R(2) = 0.947). CONCLUSIONS Despite lower cyclic loading on posterior sutures, the weaker posterior mitral annular tissue creates higher risk of dehiscence, apparently because of reduced collagen content. Sutures placed atop the trigones are less secure than predicted, because of a combination of reduced collagen and higher overall rigidity in this region. These findings highlight the inter-trigonal tissue as the superior anchor and have implications on the design and implantation techniques for next-generation mitral prostheses.
منابع مشابه
A virtual sizing tool for mitral valve annuloplasty.
Functional mitral regurgitation, a backward leakage of the mitral valve, is a result of left ventricular growth and mitral annular dilatation. Its gold standard treatment is mitral annuloplasty, the surgical reduction in mitral annular area through the implantation of annuloplasty rings. Recurrent regurgitation rates may, however, be as high as 30% and more. While the degree of annular downsizi...
متن کاملMitral Valve Annuloplasty Ring Dehiscence Diagnosed Intraoperative With Real-Time 3D Transesophageal Echocardiogram
Mitral annular calcification (MAC) is often a result of the accumulation of lipids around the annulus, which can lead to degeneration and calcification of the valve. Multiple risk factors have been associated with the progression of MAC and life-threatening complications such as the early mitral valve annuloplasty dehiscence. Our case describes the different risk factors for annuloplasty dehisc...
متن کاملSaddle-shaped mitral valve annuloplasty rings experience lower forces compared with flat rings.
BACKGROUND New insight into the 3D dynamic behavior of the mitral valve has prompted a reevaluation of annuloplasty ring designs. Force balance analysis indicates correlation between annulus forces and stresses in leaflets and chords. Improving this stress distribution can intuitively enhance the durability of mitral valve repair. We tested the hypothesis that saddle-shaped annuloplasty rings h...
متن کاملHow do annuloplasty rings affect mitral annular strains in the normal beating ovine heart?
BACKGROUND We hypothesized that annuloplasty ring implantation alters mitral annular strains in a normal beating ovine heart preparation. METHODS AND RESULTS Sheep had 16 radiopaque markers sewn equally spaced around the mitral annulus. Edwards Cosgrove partial flexible band (COS; n=12), St Jude complete rigid saddle-shaped annuloplasty ring (RSA; n=10), Carpentier-Edwards Physio (PHY; n=11),...
متن کاملInfective endocarditis presenting initially with ileus complicated by dehiscence of annuloplasty ring
BACKGROUND Infective endocarditis (IE) on an annuloplasty ring dehiscence is uncommon after mitral valve repair. CASE PRESENTATION A 53-year-old man underwent mitral annuloplasty with a 24-mm ring for posterior mitral valve prolapse. He underwent repeat valve repair for recurrent mitral valve regurgitation 4 years later. He was re-hospitalised complaining of vomiting, nausea, general fatigue ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Annals of thoracic surgery
دوره 102 2 شماره
صفحات -
تاریخ انتشار 2016