Validation of a predictive method for an accurate assessment of resting energy expenditure in medical mechanically ventilated patients.

نویسندگان

  • Jean-François Savard
  • Christophe Faisy
  • Nicolas Lerolle
  • Emmanuel Guerot
  • Jean-Luc Diehl
  • Jean-Yves Fagon
چکیده

OBJECTIVE Use comparison with indirect calorimetry to confirm the ability of our previously described equation to predict resting energy expenditure in mechanically ventilated patients. DESIGN Prospective, validation study. SETTING Eighteen-bed, medical intensive care unit at a teaching hospital. PATIENTS All adult patients intubated >24 hrs were assessed for eligibility. Exclusion criteria were clinical situations that could contribute to erroneous calorimetric measurements. INTERVENTIONS Resting energy expenditure was calculated using the original Harris-Benedict equations and those corrected for usual stress factors, the Swinamer equation, the Fusco equation, the Ireton-Jones equation, and our equation: resting energy expenditure (kcal/day) = 8 x weight (kg) + 14 x height (cm) + 32 x minute ventilation (L/min) + 94 x temperature (degrees C) - 4834. MEASUREMENTS AND MAIN RESULTS Resting energy expenditure was measured by indirect calorimetry for the 45 included patients. Resting energy expenditure calculated with our predictive model correlated with the measured resting energy expenditure (r2 = .62, p < .0001), and Bland-Altman analysis showed a mean bias of -192 +/- 277 kcal/day, with limits of agreement ranging from -735 to 351 kcal/day. Resting energy expenditure calculated with the Harris-Benedict equations was more weakly correlated with measured resting energy expenditure (r2 = .41, p < .0001), with Bland-Altman analysis showing a mean bias of 279 +/- 346 kcal/day between them and the limits of agreement ranging from -399 to 957 kcal/day. Applying usual stress-correction factors to the Harris-Benedict equations generated wide variability, and the correlation with measured resting energy expenditure was poorer (r2 = .18, p < .0001), with Bland-Altman analysis showing a mean bias of -357 +/- 750 kcal/day and limits of agreement ranging from -1827 to 1113 kcal/day. The use of the Swinamer, Fusco, or Ireton-Jones predictive methods yielded weaker correlation between calculated and measured resting energy expenditure (r2 = .41, p < .0001; r2 = .38, p < .0001; r2 = .39, p < .0001, respectively) than our equation, and Bland-Altman analysis showed no improvement in agreement and variability between methods. CONCLUSIONS The Faisy equation, based on static (height), less stable (weight), and dynamic biometric variables (temperature and minute ventilation), provided precise and unbiased resting energy expenditure estimations in mechanically ventilated patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A predictive equation for determination of resting energy expenditure in mechanically ventilated patients.

STUDY OBJECTIVE To evaluate an equation that estimates resting energy expenditure from two easily obtained measurements--expired carbon dioxide and minute ventilation, and compare the results of this equation with standard methods of estimating and measuring caloric expenditure in mechanically ventilated patients. DESIGN Prospective evaluation in a consecutive, unselected cohort. SETTING Me...

متن کامل

Measuring energy expenditure in the intensive care unit: a comparison of indirect calorimetry by E-sCOVX and Quark RMR with Deltatrac II in mechanically ventilated critically ill patients.

BACKGROUND Indirect calorimetry allows the determination of energy expenditure in critically ill patients by measuring oxygen consumption (VO2) and carbon dioxide production (VCO2). Recent studies have demonstrated variable performance of "breath-by-breath" instruments compared to mixing chamber technology. The aim of this study was to validate two modern devices (E-sCOVX and Quark RMR) against...

متن کامل

Evaluation of the Effect of Nebulized N-Acetylcysteine on Respiratory Secretions in Mechanically Ventilated Patients: Randomized Clinical Trial

Background: The purpose of our study was to evaluate an inexpensive and available method to reduce mucous impactions in mechanically ventilated patients.Methods: This randomized clinical trial was conducted on 40 mechanically ventilated patients aged 15-90 years. The patients were randomly allocated into two arms; 20 cases and 20 controls. The cases received N-acetylcysteine via their nebulizer...

متن کامل

Effect of Oral Drop Gastrolit (Zataria multiflora) on Gastric Residual Volume in Mechanically Ventilated Patients Hospitalized in the Intensive Care Units

Background: Proper nutritional support is one of the important caring aspects in patients who were hospitalized in ICU. Objective: This study was done to investigate Oral Drop Gastrolit effect on the gastric residual volume (GRV) in mechanically ventilated patients hospitalized in ICU. Methods: In this clinical trial, 50 mechanically ventilated patients were recruited using convenience sampli...

متن کامل

مقایسه‌ی میزان متابولیسم استراحت، ترکیب بدن و پروفایل لیپیدی در زنان مبتلا به کم‌کاری آشکار تیروئید تحت درمان با لووتیروکسین با و بدون علائم بالینی

Background: The major cause of obesity is an imbalance between energy intake and energy expenditure and resting energy expenditure (REE) is the most important determining factor in metabolism because it can reduce obesity and body fat mass gain. Overt hypothyroidism is associated with a lower resting energy expenditure (REE). With treatment, the resting energy expenditure (REE) will be normal. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Critical care medicine

دوره 36 4  شماره 

صفحات  -

تاریخ انتشار 2008