Modelflow underestimates cardiac output in heat-stressed individuals.

نویسندگان

  • Manabu Shibasaki
  • Thad E Wilson
  • Morten Bundgaard-Nielsen
  • Thomas Seifert
  • Niels H Secher
  • Craig G Crandall
چکیده

An estimation of cardiac output can be obtained from arterial pressure waveforms using the Modelflow method. However, whether the assumptions associated with Modelflow calculations are accurate during whole body heating is unknown. This project tested the hypothesis that cardiac output obtained via Modelflow accurately tracks thermodilution-derived cardiac outputs during whole body heat stress. Acute changes of cardiac output were accomplished via lower-body negative pressure (LBNP) during normothermic and heat-stressed conditions. In nine healthy normotensive subjects, arterial pressure was measured via brachial artery cannulation and the volume-clamp method of the Finometer. Cardiac output was estimated from both pressure waveforms using the Modeflow method. In normothermic conditions, cardiac outputs estimated via Modelflow (arterial cannulation: 6.1 ± 1.0 l/min; Finometer 6.3 ± 1.3 l/min) were similar with cardiac outputs measured by thermodilution (6.4 ± 0.8 l/min). The subsequent reduction in cardiac output during LBNP was also similar among these methods. Whole body heat stress elevated internal temperature from 36.6 ± 0.3 to 37.8 ± 0.4°C and increased cardiac output from 6.4 ± 0.8 to 10.9 ± 2.0 l/min when evaluated with thermodilution (P < 0.001). However, the increase in cardiac output estimated from the Modelflow method for both arterial cannulation (2.3 ± 1.1 l/min) and Finometer (1.5 ± 1.2 l/min) was attenuated compared with thermodilution (4.5 ± 1.4 l/min, both P < 0.01). Finally, the reduction in cardiac output during LBNP while heat stressed was significantly attenuated for both Modelflow methods (cannulation: -1.8 ± 1.2 l/min, Finometer: -1.5 ± 0.9 l/min) compared with thermodilution (-3.8 ± 1.19 l/min). These results demonstrate that the Modelflow method, regardless of Finometer or direct arterial waveforms, underestimates cardiac output during heat stress and during subsequent reductions in cardiac output via LBNP.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Finapres arterial pulse wave analysis with Modelflow is not a reliable non-invasive method for assessment of cardiac output.

Non-invasive continuous monitoring of cardiac output could be very useful in clinical care and in research settings, particularly in elderly subjects. We studied whether Finapres arterial pulse wave analysis with Modelflow is a reliable non-invasive method for the assessment of cardiac output in healthy elderly subjects. We compared Modelflow cardiac output (MFCO) with thermodilution cardiac ou...

متن کامل

Correction of cardiac output obtained by Modelflow from finger pulse pressure profiles with a respiratory method in humans.

The beat-by-beat non-invasive assessment of cardiac output (Q litre x min(-1)) based on the arterial pulse pressure analysis called Modelflow can be a very useful tool for quantifying the cardiovascular adjustments occurring in exercising humans. Q was measured in nine young subjects at rest and during steady-state cycling exercise performed at 50, 100, 150 and 200 W by using Modelflow applied ...

متن کامل

Less invasive determination of cardiac output from the arterial pressure by aortic diameter-calibrated pulse contour.

BACKGROUND Cardiac output by modelflow pulse contour method can be monitored quantitatively and continuously only after an initial calibration, to adapt the model to an individual patient. The modelflow method computes beat-to-beat cardiac output (COmf) from the radial artery pressure, by simulating a three-element model of aortic impedance with post-mortem data from human aortas. METHODS In ...

متن کامل

Effect of heat stress on cardiac output and systemic vascular conductance during simulated hemorrhage to presyncope in young men.

During moderate actual or simulated hemorrhage, as cardiac output decreases, reductions in systemic vascular conductance (SVC) maintain mean arterial pressure (MAP). Heat stress, however, compromises the control of MAP during simulated hemorrhage, and it remains unknown whether this response is due to a persistently high SVC and/or a low cardiac output. This study tested the hypothesis that an ...

متن کامل

CARDIOVASCULAR Monitoring non-invasive cardiac output and stroke volume during experimental human hypovolaemia and resuscitation

Key points † Controlled application of lower body negative pressure simulated hypovolaemia and resuscitation in human subjects. † Thoracic electrical bioimpedance, and arterial blood pressure (ABP) analysis by the Long Time Interval method, were the most discriminatory measurements. † The Modelflow method of ABP analysis effectively tracked hypovolaemia, but underestimated resuscitation. † Puls...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of physiology. Regulatory, integrative and comparative physiology

دوره 300 2  شماره 

صفحات  -

تاریخ انتشار 2011