Biomechanical testing of transcapsular meniscal repair

نویسندگان

  • Ryo Iuchi
  • Tatsuo Mae
  • Konsei Shino
  • Tomohiko Matsuo
  • Hideki Yoshikawa
  • Ken Nakata
چکیده

BACKGROUND All of previous biomechanical studies on meniscal repair have examined the meniscus itself without synovial membrane and capsule, although in the clinical setting, the meniscal repair is generally performed including capsule. Therefore, biomechanical properties of transcapsular meniscal repair are unclear. Thus, this study aimed to clarify the biomechanical properties of transcapsular meniscal repair. METHODS In 70 porcine femur-medial meniscus-tibia complexes with capsules, longitudinal meniscal tears were repaired using different suture techniques (inside-out or all-inside technique), suture methods (vertical or horizontal methods), and numbers of sutures (single or double). A cyclic loading test between 5 and 20 N for 300 cycles was performed followed by a load-to-failure test. RESULTS Tears repaired by the all-inside technique presented significantly larger widening (0.88 ± 0.38 mm) than those by the inside-out technique (0.51 ± 0.39 mm) during the cyclic loading test (P = 0.035). The horizontal suture presented significantly lower ultimate failure load (62.5 ± 15.5 N) in the all-inside technique than in the vertical suture (79.7 ± 13.0 N; P = 0.018). The stacked suture had a significantly higher failure load (104.6 ± 12.5 N) than the parallel suture (83.3 ± 12.6 N; P = 0.001). Furthermore, the double suture presented significantly higher failure loads (83.3 ± 12.6 N and 104.6 ± 20.4 N) than the single suture with both inside-out (58.8 ± 8.3 N; P = 0.001) and all-inside (79.7 ± 13.0 N; P = 0.022) techniques. CONCLUSIONS Upon comparison of the suture techniques, the inside-out technique provided a more stable fixation at the repair site than the all-inside technique during the cyclic test. Among the suture methods, the vertical suture had more desirable biomechanical properties than the horizontal suture as demonstrated by smaller widening during the cyclic test and the larger load to failure. The stacked suture created a stronger fixation than the parallel suture. In terms of the number of sutures, the double suture had superior biomechanical properties compared with the single suture.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Correlation of meniscal T2* with multiphoton microscopy, and change of articular cartilage T2 in an ovine model of meniscal repair.

OBJECTIVE To correlate meniscal T2* relaxation times using ultra-short echo time (UTE) magnetic resonance imaging (MRI) with quantitative microscopic methods, and to determine the effect of meniscal repair on post-operative cartilage T2 values. DESIGN A medial meniscal tear was created and repaired in the anterior horn of one limb of 28 crossbred mature ewes. MR scans for morphological evalua...

متن کامل

Dynamic loading enhances integrative meniscal repair in the presence of interleukin-1.

OBJECTIVE Meniscal tears are a common knee injury and increased levels of interleukin-1 (IL-1) have been measured in injured and degenerated joints. Studies have shown that IL-1 decreases the shear strength, cell accumulation, and tissue formation in meniscal repair interfaces. While mechanical stress and IL-1 modulate meniscal biosynthesis and degradation, the effects of dynamic loading on men...

متن کامل

Load to failure testing of new meniscal repair devices.

PURPOSE New all-inside meniscal repair devices include those combining sutures with anchors and that allow for an "adjustable" repair. This study's purpose was to compare the failure strength of new meniscal repair devices with suture repairs. TYPE OF STUDY Experimental laboratory biomechanical study. METHODS A single repair was placed in a vertical longitudinal peripheral tear made in fres...

متن کامل

Tensile and shear loading stability of all-inside meniscal repairs: an in vitro biomechanical evaluation.

BACKGROUND Most biomechanical studies for evaluation of the structural properties of meniscal repairs have been performed in tensile loading scenarios perpendicular to the circumferential meniscal fibers. However, meniscal repair constructs are also exposed to shear forces parallel to the circumferential meniscal fibers during healing, particularly in the midportion of the meniscus. HYPOTHESI...

متن کامل

Clinical Results of Meniscal Repair Using Submeniscal Horizontal Sutures

Background:  Parts of the implants placed over the meniscus during meniscal repair can wear down the cartilage in the contact zones and cause chronic synovitis. Placing horizontal sutures under the meniscus may overcome this potential hazard. The purpose of this prospective study was to evaluate the midterm results of arthroscopic meniscal repair using submeniscally placed out-in horizontal sut...

متن کامل