Comparison of gradient- and spin-echo imaging: CBF, CBV, and MTT measurements by bolus tracking.
نویسندگان
چکیده
The authors measured cerebral blood flow (CBF), cerebral blood volume (CBV), and mean transit time (MTT) in pigs by gadodiamide bolus injections and the bolus tracking technique. Two different pulse sequences were applied and compared: gradient-echo (GE) and spin-echo (SE) echoplanar imaging (EPI). After normalization of CBF and CBV values to the area under the arterial input function (AIF), a linear relation between the two methods was found, suggesting that a previous normalization approach for determining absolute CBF by SE EPI may be extended to GE EPI measurements. The ratio between CBV values measured with GE and SE [CBV (GE)/CBV (SE)] was 2.96. Assuming that the GE acquisition reflects total CBV, our findings suggest that SE is sensitive to 34% (1/2.96) of the total vasculature. The corresponding ratio for CBF was 2.53. There was no significant difference in these two ratios, suggesting that MTT estimates derived from GE and SE EPI measurements are comparable. The findings suggest that SE and GE are equally useful in clinical measurements of functional parameters such as CBF, CBV, and MTT in the brain. J. Magn. Reson. Imaging 2000;12:411-416.
منابع مشابه
Whole brain quantitative CBF, CBV, and MTT measurements using MRI bolus tracking: implementation and application to data acquired from hyperacute stroke patients.
A robust whole brain magnetic resonance (MR) bolus tracking technique based on indicator dilution theory, which could quantitatively calculate cerebral blood flow (CBF), cerebral blood volume (CBV), and mean transit time (MTT) on a regional basis, was developed and tested. T2*-weighted gradient-echo echoplanar imaging (EPI) volumes were acquired on 40 hyperacute stroke patients after gadolinium...
متن کاملRapid Measurement of Oxygen Extraction Fraction (OEF) Maps using a Combined Multiple Gradient and Spin Echo Bolus Contrast Sequence
Introduction: In the last few years, we have developed an MRI method that allows high-resolution quantitative measurements of the level of blood oxygenation (SO2) in the brain [1]. The technique is based on the specific extraction of the oxygenation information from baseline T2* measurements using a mathematical model and independent measurements of T2, B0, and the cerebral blood volume (CBV). ...
متن کاملSimultaneous perfusion and permeability measurements using combined spin- and gradient-echo MRI.
The purpose of this study was to estimate magnetic resonance imaging-based brain perfusion parameters from combined multiecho spin-echo and gradient-echo acquisitions, to correct them for T₁₋, T₂₋, and T₂₋*-related contrast agent (CA) extravasation effects, and to simultaneously determine vascular permeability. Perfusion data were acquired using a combined multiecho spin- and gradient-echo (SAG...
متن کاملMulti-delay multi-parametric arterial spin-labeled perfusion MRI in acute ischemic stroke — Comparison with dynamic susceptibility contrast enhanced perfusion imaging☆
The purpose of the present study was to present a multi-delay multi-parametric pseudo-continuous arterial spin labeling (pCASL) protocol with background suppressed 3D GRASE (gradient and spin echo) readout for perfusion imaging in acute ischemic stroke. PCASL data at 4 post-labeling delay times (PLD = 1.5, 2, 2.5, 3 s) were acquired within 4.5 min in 24 patients (mean age 79.7 ± 11.4 years; 11 ...
متن کاملOptimizing dynamic T2* MR imaging for measurement of cerebral blood flow using infusions for cerebral blood volume.
We describe an approach to measuring cerebral blood flow (CBF) based on independent measurements of cerebral blood volume (CBV) and mean transit time (MTT) with calculation of CBF by using the central volume theorem: CBF = CBV / MTT. This permits optimization of the individual acquisitions and analyses. In particular, measurement of CBV during contrast infusion, rather than simultaneously with ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of magnetic resonance imaging : JMRI
دوره 12 3 شماره
صفحات -
تاریخ انتشار 2000