Simultaneous colorimetric determination of morphine and ibuprofen based on the aggregation of gold nanoparticles using partial least square
نویسندگان
چکیده
In this work a new method is presented for simultaneous colorimetric determination of morphine(MOR) and ibuprofen(IBU) based on the aggregation of citrate-capped gold nanoparticles (AuNPs). Citrate-capped gold nanoparticles were aggregated in the presence of morphine and ibuprofen. The difference in kinetics of AuNPs aggregation in the presence of morphine / ibuprofen was used for simultaneous analysis of morphine and ibuprofen. The formation and size of synthesized Au NPs and the aggregated forms were monitored by infra-Red (IR) spectroscopy and transmission electron microscopy (TEM) respectively.. By adding morphine or ibuprofen the absorbance was decreased at 520 nm and increased at 620 nm. The difference in kinetic profiles of aggregation was applied for simultaneous analysis of MOR and IBU using partial least square regression as an efficient multivariate calibration method. The number of PLS latent variables was optimized by leave-one-out cross-validation method using predicted residual error sum of square. The proposed model exhibited a high capability in simultaneous prediction of MOR and IBU concentrations in real samples. Our results showed linear ranges of 1.33-33.29 µg/mL (R2=0.9904) and 0.28-6.9 µg/mL (R2=0.9902) for MOR and IBU respectively with low detection limits of 0.15 and 0.03 µg/mL(S/N=5).
منابع مشابه
Spectrophotometric Determination of 4-Hydroxy-2-mercapto-6-methylpyrimidine Based on Aggregation of Colloidal Gold Nanoparticles
We report herein the development of a highly sensitive colorimetric method for the detection of 4-hydroxy-2-mercapto-6-methylpyrimidine (MTU) which acts as an anti-thyroid drug utilizing citrate capped gold nanoparticles (Au-NPs). This thiol-containing molecule exhibits intriguing affinity with Au-NPs. The reactivity involves the displacement of the citrate shell by the thiolate shell followed ...
متن کاملSimultaneous Spectrophotometric Determination of Iron, Cobalt and Copper by Partial Least-Squares Calibration Method in Micellar Medium
Iron, cobalt and copper are metals, which appear together in many real samples, both natural and artificial. Recently a classical univariate micellar colorimetric method has been developed for determination of these metal ions. The organized molecular assemblies such as micelles are used in spectroscopic measurements due to their possible effects on the systems of interest. The ability of mi...
متن کاملSimultaneous Spectrophotometric Determination of Iron, Cobalt and Copper by Partial Least-Squares Calibration Method in Micellar Medium
Iron, cobalt and copper are metals, which appear together in many real samples, both natural and artificial. Recently a classical univariate micellar colorimetric method has been developed for determination of these metal ions. The organized molecular assemblies such as micelles are used in spectroscopic measurements due to their possible effects on the systems of interest. The ability of mi...
متن کاملLeast-squares support vector machine and its application in the simultaneous quantitative spectrophotometric determination of pharmaceutical ternary mixture
This paper proposes the least-squares support vector machine (LS-SVM) as an intelligent method applied on absorption spectra for the simultaneous determination of paracetamol (PCT), caffeine (CAF) and ibuprofen (IB) in Novafen. The signal to noise ratio (S/N) increased. Also, In the LS - SVM model, Kernel parameter (σ2) and capacity factor (C) were optimized. Excellent prediction was shown usin...
متن کاملSimultaneous spectrophotometric determination of lead, copper and nickel using xylenol orange by partial least squares
A partial least squares (PLS) calibration model was developed for the simultaneous spectrophotometricdetermination of Pb (ΙΙ), Cu (ΙΙ) and Ni (ΙΙ) using xylenol orange as a chromogenic reagent. The parameterscontrolling behavior of the system were investigated and optimum conditions were selected. The calibrationgraphs were linear in the ranges of 0.0–9.091, 0.0–2.719 and 0.0–2.381 ppm for lead...