Comparison of FilmArray and Quantitative Real-Time Reverse Transcriptase PCR for Detection of Zaire Ebolavirus from Contrived and Clinical Specimens.

نویسندگان

  • Timothy R Southern
  • Lori D Racsa
  • César G Albariño
  • Paul D Fey
  • Steven H Hinrichs
  • Caitlin N Murphy
  • Vicki L Herrera
  • Anthony R Sambol
  • Charles E Hill
  • Emily L Ryan
  • Colleen S Kraft
  • Shelley Campbell
  • Tara K Sealy
  • Amy Schuh
  • James C Ritchie
  • G Marshall Lyon
  • Aneesh K Mehta
  • Jay B Varkey
  • Bruce S Ribner
  • Kent P Brantly
  • Ute Ströher
  • Peter C Iwen
  • Eileen M Burd
چکیده

Rapid, reliable, and easy-to-use diagnostic assays for detection of Zaire ebolavirus (ZEBOV) are urgently needed. The goal of this study was to examine the agreement among emergency use authorization (EUA) tests for the detection of ZEBOV nucleic acids, including the BioFire FilmArray BioThreat (BT) panel, the FilmArray BT-E panel, and the NP2 and VP40 quantitative real-time reverse transcriptase (qRT) PCR assays from the Centers for Disease Control and Prevention (CDC). Specimens used in this study included whole blood spiked with inactivated ZEBOV at known titers and whole-blood, plasma, and urine clinical specimens collected from persons diagnosed with Ebola virus disease (EVD). The agreement for FilmArray and qRT-PCR results using contrived whole-blood specimens was 100% (6/6 specimens) for each ZEBOV dilution from 4 × 10(7) to 4 × 10(2) 50% tissue culture infective dose (TCID50)/ml, as well as the no-virus negative-control sample. The limit of detection for FilmArray and qRT-PCR assays with inactivated ZEBOV, based on duplicate positive results, was determined to be 4 × 10(2) TCID50/ml. Rates of agreement between FilmArray and qRT-PCR results for clinical specimens from patients with EVD were 85% (23/27 specimens) for whole-blood specimens, 90% (18/20 specimens) for whole-blood specimens tested by FilmArray testing and matched plasma specimens tested by qRT-PCR testing, and 85% (11/13 specimens) for urine specimens. Among 60 specimens, eight discordant results were noted, with ZEBOV nucleic acids being detected only by FilmArray testing in four specimens and only by qRT-PCR testing in the remaining four specimens. These findings demonstrate that the rapid and easy-to-use FilmArray panels are effective tests for evaluating patients with EVD.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A reverse transcriptase-loop mediated isothermal amplification assay (RT-LAMP) for rapid detection of bovine viral diarrhea virus 1 and 2

Bovine viral diarrhea virus (BVDV) is a pathogen that infects cattle, and is globally important. It causes substantial financial losses to the livestock industry. In the current study, a one-step reverse transcriptase-loop-mediated isothermal amplification (RT-LAMP) assay was set up for rapid and efficient detection of BVDV. For this purpose, four primers were designed to recognize six distinct...

متن کامل

Evaluation of RealStar Reverse Transcription–Polymerase Chain Reaction Kits for Filovirus Detection in the Laboratory and Field

BACKGROUND  Diagnosis of Ebola virus (EBOV) disease (EVD) requires laboratory testing. METHODS  The RealStar Filovirus Screen reverse transcription-polymerase chain reaction (RT-PCR) kit and the derived RealStar Zaire Ebolavirus RT-PCR kit were validated using in vitro transcripts, supernatant of infected cell cultures, and clinical specimens from patients with EVD. RESULTS  The Filovirus S...

متن کامل

Development and Evaluation of Real-Time Reverse Transcription Polymerase Chain Reaction Test for Quantitative and Qualitative Recognition of H5 Subtype of Avian Influenza Viruses

Avian influenza viruses (AIV) affect a wide range of birds and mammals, cause severe economic damage to the poultry industry, and pose a serious threat to humans. Highly pathogenic avian influenza viruses (HPAI) H5N1 were first identified in Southeast Asia in 1996 and spread to four continents over the following years. The viruses have caused high mortality in chickens and various bird species ...

متن کامل

تشخیص میکرومتاستاز با مارکر CEA در نمونه‌های خون محیطی و مغز استخوان افراد مبتلا به سرطان معده با روش Real-Time PCR

Normal 0 false false false EN-US X-NONE AR-SA MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal" mso-tsty...

متن کامل

Rapid Detection of COVID-19 by RT-LAMP PCR Technique and its Comparison with Real-Time RT-PCR Method

Rapid antigen and antibody, serological tests, and RT ‑ PCR-based molecular methods are widely used for the detection of microorganisms worldwide. Objectives: This study aimed by Isothermal nucleic acid amplification techniques to detect the covid-19. Methods: In this study, 200 samples of nasopharynx and oropharynx were collected from Jamaran Heart Hospital in Tehran. Covid -19 was exami...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 53 9  شماره 

صفحات  -

تاریخ انتشار 2015