Effect of changes in heart rate on pressure half time in normally functioning mitral valve prostheses.

نویسندگان

  • J Chambers
  • N McLoughlin
  • A Rapson
  • G Jackson
چکیده

To test the validity of a relation between the pressure half time and the diastolic time interval, previously shown in a pulse duplication system, eight patients with prosthetic mitral valves and permanent pacemaker systems were studied. Recordings were made from the apex by continuous wave or pulsed Doppler echocardiography at heart rates between 75 and 150 beats/min. The pressure half time was found to be closely correlated with the diastolic time interval although there was individual variation and in three prostheses the pressure half time attained a plateau when the diastolic time interval was more than 300 ms. It is likely that the orifice area is the main controller of pressure half time where there is stenosis of the prosthesis, but that other factors such as ventricular or atrial compliance and the diastolic time interval may modify or obscure the effect of orifice area in normally functioning prosthetic valves.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Limitations of Doppler ultrasound in the assessment of the function of prosthetic mitral valves.

Pressure half time has been assumed to be a relatively flow-independent measure of orifice area, but it may also be influenced by atrial and ventricular factors. Pressure half time and peak left ventricular inflow velocity were measured by continuous wave Doppler ultrasound in 164 patients with normally functioning Carpentier-Edwards, Björk-Shiley, and Starr-Edwards mitral prostheses. Pressure ...

متن کامل

Auscultatory characteristics of normally functioning Lillehei-Kaster, Björk-Shiley, and St Jude heart valve prostheses.

Auscultatory and echocardiographic and phonocardiographic studies were performed on 26 patients who had a total of 11 Lillehei-Kaster, 16 Björk-Shiley, and 18 St Jude heart valve prostheses functioning normally in the aortic or mitral positions or both. With all types and positions of prostheses a distinct closing sound was always detected. It was frequently heard in two parts which, according ...

متن کامل

Doppler sonographic evaluation of mechanical and bioprosthetic mitral valve prostheses during exercise with a rate corrected pressure half time.

OBJECTIVE To compare the effect of exercise on pressure half time in patients with mechanical or bioprosthetic mitral valves. A relative pressure half time (pressure half time as a percentage of RR interval) was used in an attempt to correct for the shortening of the diastolic time interval caused by the increase in heart rate during exercise and thus to uncover the effects of valve design on p...

متن کامل

Analysis of dynamics of mitral Starr-Edwards valve prosthesis using reflected ultrasound.

The speed of closure of the mitral valve during diastole, as recorded by ultrasonocardiography, is reduced in patients with mitral stenosis. A pattern of movement similar to that of severe mitral stenosis is seen in recordingsfrom patients with normally functioning mitral Starr-Edwards prostheses. Simultaneous ultrasound recordings of ball and cage movements show that the prosthetic valve remai...

متن کامل

Right sided heart evaluation after successful mitral valve replacement.

Introduction: It is well-documented that right-sided heart dysfunction and significant tricuspid valve regurgitation (TVR) have adverse effects on patient outcomes after left-sided heart valve surgery. Therefore, the evaluation of right ventriclular (RV) function and TR severity in patients who had undergone mitral valve replacement (MVR), associated with/without concomitant su...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • British heart journal

دوره 60 6  شماره 

صفحات  -