Registration of emission and transmission whole-body scintillation-camera images.
نویسندگان
چکیده
UNLABELLED In this work, a method for registration of whole-body (WB) scintillation-camera images is presented. The primary motive for the development is to perform activity quantification using the conjugate view method on an image basis. Accurate image registration is required for sequential anterior and posterior scans, for serial emission images for analysis of the biokinetics, and for transmission and emission images for a pixel-based attenuation correction. METHODS Registration is performed by maximization of the mutual information. The spatial transformation has been tailored for the registration of WB images and is composed of global and local transformations, including rigid, projective, and curved transformations. A coarse registration is first performed using cross-correlation and direct pixel scaling. Optimization is then performed in a sequence, beginning with the 2 legs independently, followed by the upper body and head. Evaluation is performed for clinical images of an (131)I-labeled monoclonal antibody and for Monte Carlo-simulated images. An anthropomorphic WB computer phantom, which has been especially modified to match the patient position during WB scanning, is used for the simulations. RESULTS For simulated images, registration errors are within 1 pixel (<3.6 mm) for a sufficient image count level. Separate evaluation of the influence of noise shows that the errors increase below a total image count of approximately 10(5) (signal-to-noise ratio, approximately 4). For clinical evaluations, the deviations between point markers are 9 +/- 5 mm. CONCLUSION An automatic registration method for WB images has been developed, which is applicable to emission-emission and transmission-emission registration. This method has been applied in more than 50 clinical studies and has shown to be robust and reliable.
منابع مشابه
An activity quantification method based on registration of CT and whole-body scintillation camera images, with application to 131I.
UNLABELLED This article presents a new method for conjugate view activity quantification for 131I-labeled monoclonal antibody distribution. METHODS The method is based on the combined use of images from 3 modalities: whole-body (WB) scintillation camera scanning, WB transmission scanning using 57Co, and CT. All images are coaligned using a recently developed program for the registration of WB...
متن کاملCT-PET weighted image fusion for separately scanned whole body rat.
PURPOSE The limited resolution and lack of spatial information in positron emission tomography (PET) images require the complementary anatomic information from the computed tomography (CT) and/or magnetic resonance imaging (MRI). Therefore, multimodality image fusion techniques such as PET/CT are critical in mapping the functional images to structural images and thus facilitate the interpretati...
متن کاملAutomated 3-dimensional registration of stand-alone (18)F-FDG whole-body PET with CT.
UNLABELLED Image registration and fusion of whole-body (18)F-FDG PET with thoracic CT would allow combination of anatomic detail from CT with functional PET information, which could lead to improved diagnosis or PET-based radiotherapy planning. METHODS We have designed a practical and fully automated algorithm for the elastic 3-dimensional image registration of whole-body PET and CT images, w...
متن کاملMonte Carlo Study of the Effect of Backscatter Materail Thickness on 99mTc Source Response in Single Photon Emission Computed Tomography
Introduction SPECT projections are contaminated by scatter radiation, resulting in reduced image contrast and quantitative errors. Backscatter constitutes a major part of the scatter contamination in lower energy windows. The current study is an evaluation of the effect of backscatter material on FWHM and image quality investigated by Monte Carlo simulation. Materials and Methods SIMIND program...
متن کاملSystemic atherosclerotic plaque vulnerability in patients with Coronary Artery Disease with a single Whole Body [FDG]PET-CT scan
Objective(s): Cardiovascular disease is a leading cause of morbimortality with over half cardiovascular events occurring in the asymptomatic population by traditional risk stratification. This preliminary study aimed to evaluate systemic plaque vulnerability in patients with prior Coronary Artery Disease (CAD) with a single Whole Body [FDG] PET-CT scan in terms of plaq...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of nuclear medicine : official publication, Society of Nuclear Medicine
دوره 42 10 شماره
صفحات -
تاریخ انتشار 2001