Computerized tomography evaluation of a resorbable implant after transforaminal lumbar interbody fusion.
نویسندگان
چکیده
OBJECT Synthetic bioabsorbable implants have recently been introduced in spinal surgery; consequently, the indications, applications, and results are still evolving. The authors used absorbable interbody spacers (Medtronic Sofamor Danek, Memphis, TN) packed with recombinant bone morphogenetic protein (Infuse; Medtronic Sofamor Danek) for single- and multiple-level transforaminal lumbar interbody fusion (TLIF) procedures over a period of 18 months. This is a consecutive case series in which postoperative computerized tomography (CT) scanning was used to assess fusion status. METHODS There were 22 patients (17 men, five women; 39 fusion levels) whose mean age was 41.6 years (range 23-70 years) and in whom the mean follow-up duration was 12.4 months (range 6-18 months). Bridging bone was noted as early as the 3-month postoperative CT scan when obtained; solid arthrodesis was routinely noted between 6 and 12 months in 38 (97.4%) of 39 fusion levels. In patients who underwent repeated CT scanning, the fusion mass appeared to increase with time, whereas the disc space height remained stable. Although the results are early (mean 12-month follow-up duration), there was only one noted asymptomatic delayed union/nonunion at L5-S1 in a two-level TLIF with associated screw breakage. There were no infections or complications related to the cages. CONCLUSIONS The bioabsorbable cages appear to be a viable alternative to metal interbody spacers, and may be ideally suited to spinal interbody applications because of their progressive load-bearing properties.
منابع مشابه
Instrumented transforaminal lumbar interbody fusion in surgical treatment of recurrent disc herniation
Background :The incidence of recurrence in patients undergoing primary discectomy due to lumbar disc herniation (LDH), is regularly reported as 5-15%. In this study we aimed to evaluate surgical outcome of instrumented transforaminal lumbar interbody fusion (TLIF) in the patients suffering from recurrent LDH. Methods : We retrospectively studied 51 patients (30 female, 21 male) from August ...
متن کاملClinical and Radiographic Outcomes of Transforaminal Lumbar Interbody Fusion in Patients with Osteoporosis
Study Design Retrospective review. Objective To compare clinical outcomes after transforaminal lumbar interbody fusion (TLIF) in patients with and patients without osteoporosis. Methods We reviewed all patients with 6-month postoperative radiographs and computed tomography (CT) scans for evaluation of the interbody cage. CT Hounsfield unit (HU) measurements of the instrumented vertebral body we...
متن کاملAn Innovative Use of Cortoss Bone Cement to Stabilize a Nonunion after Interbody Fusion
A 65-year-old male originally had surgery for spondylolisthesis at L5-S1 in 2008 and then went on to have an L4-5 transforaminal lumbar interbody fusion (TLIF) with pedicle screw fixation from L4 to S1 and interbody graft in 2010. Despite having two surgical procedures, he continued with intractable back pain and was told he had a failed lumbar fusion. When he was evaluated with a computerized ...
متن کاملTransforaminal lumbar interbody fusion for failed Graf ligamentoplasty: a report of two cases.
We report 2 cases of transforaminal lumbar interbody fusion for failed Graf ligamentoplasty. Both patients had residual or recurrent low back pain and leg pain after Graf ligamentoplasty, caused by lumbar segmental instability or narrowing of their intervertebral foramens. The pain improved markedly after the revision surgery. We recommend transforaminal lumbar interbody fusion for failed Graf ...
متن کاملFailure of a Carbon Fiber–Reinforced Polymer Implant Used for Transforaminal Lumbar Interbody Fusion
Lumbar interbody fusion is a common procedure owing to the high prevalence of degenerative spinal disorders. During such procedures, carbon fiber-reinforced polymer (CFRP) cages are frequently utilized to fill the void created between adjacent vertebral bodies, to provide mechanical stability, and to carry graft material. Failure of such implants can lead to significant morbidity. We discuss th...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Neurosurgical focus
دوره 16 3 شماره
صفحات -
تاریخ انتشار 2004