Coronary sinus reflux. A source of error in the measurement of thermodilution coronary sinus flow.

نویسندگان

  • D G Mathey
  • K Chatterjee
  • J V Tyberg
  • J Lekven
  • B Brundage
  • W W Parmley
چکیده

In seven patients thermodilution coronary sinus flow (TD-CSF) was higher (164 +/- 21 ml/min) during ventricular pacing than during atrial pacing (119 +/- 21 ml/min, P less than 0.005) at identical heart rate, without an increase in the determinants of myocardial oxygen consumption. To assess the possibility of right atrial admixture in coronary sinus blood during ventricular pacing we compared electromagnetic coronary arterial blood flow (CBF) with TD-CSF in nine dogs during interventions that increased right atrial pressure. During ventricular pacing, rapid atrial pacing, pulmonary artery constriction and increased intrathoracic pressure, right atrial pressure increased and electromagnetic CBF was significantly less (41-166%) than TD-CSF. Marked reflux from the right atrium to the coronary sinus was also demonstrated by bolus injection of cold saline into the right atrium and continuous infusion of contrast material into coronary sinus. Caution needs to be exercised in interpreting TD-CSF in the presence of changing right atrial pressure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Coronary sinus blood flow and coronary haemodynamic function in children: measurement by the continuous thermodilution method with coronary sinus cannulation via the femoral vein.

In 19 children with Kawasaki disease without any cardiac sequelae the coronary sinus was cannulated via the femoral vein with a specially designed flow catheter and coronary sinus blood flow was measured by the continuous thermodilution method. There was a statistically significant positive correlation between coronary sinus blood flow and age, body surface area, and left ventricular mass, but ...

متن کامل

Measurement of coronary sinus blood flow by continuous thermodilution in man.

In 14 subjects with normal coronary arteries the mean coronary sinus blood flow was 122 25 mI/min (range, 83 to 159 ml/min). The blood flow computed per 100 g of left ventricle was 82 + 16 ml/min, which is in the range of values obtained by nitrous oxide and coincidence counting methods. In 35 patients with arteriographically confirmed coronary artery disease the mean flow was similar (128 + 20...

متن کامل

The effect of intracoronary injection of contrast medium upon coronary blood flow.

The changes in coronary blood flow in response to intracoronary injection of 3 ml of 76% Renografin were studied in 47 patients using the thermodilution technique for continuous measurement of coronary sinus blood flow. Within seconds after left coronary injection, an increase in coronary sinus flow began which peaked at an average of 53% above control in 5-10 seconds. There was a corresponding...

متن کامل

CASE REPORTS Reduction of Coronary Blood Flow during Coronary Artery Spasm Occurring Spontaneously and after Provocation by Ergonovine Maleate

A 50-year-old man suffering from recurrent chest pain accompanied by transient ST-segment elevation developed spasm of the left anterior descending coronary artery after receiving ergonovine maleate. During spontaneous chest pain, thermodilution coronary sinus blood flow fell from 96 ml/min to 46 ml/min, while the coronary sinus arteriovenous oxygen difference widened from 9.82 volumes percent ...

متن کامل

Pathophysiology and Natural History Myocardial Blood Flow

Coronary sinus flow (CSF) was measured in seven patients with normal coronary arteries (group A) during intracoronary injections of 6 ml arterial blood, 6 ml blood from the coronary sinus, 3 and 6 ml isotonic saline, 3 and 6 ml hypertonic glucose, and 6 ml of a contrast agent (sodium metrizoate). In 10 patients with coronary artery disease (group B), CSF was measured after administration of 6 m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 57 4  شماره 

صفحات  -

تاریخ انتشار 1978