Bioimpedance spectroscopy for the estimation of body fluid volumes in mice.

نویسندگان

  • M E Chapman
  • L Hu
  • C F Plato
  • D E Kohan
چکیده

Conventional indicator dilution techniques for measuring body fluid volume are laborious, expensive, and highly invasive. Bioimpedance spectroscopy (BIS) may be a useful alternative due to being rapid, minimally invasive, and allowing repeated measurements. BIS has not been reported in mice; hence we examined how well BIS estimates body fluid volume in mice. Using C57/Bl6 mice, the BIS system demonstrated <5% intermouse variation in total body water (TBW) and extracellular (ECFV) and intracellular fluid volume (ICFV) between animals of similar body weight. TBW, ECFV, and ICFV differed between heavier male and lighter female mice; however, the ratio of TBW, ECFV, and ICFV to body weight did not differ between mice and corresponded closely to values in the literature. Furthermore, repeat measurements over 1 wk demonstrated <5% intramouse variation. Default resistance coefficients used by the BIS system, defined for rats, produced body composition values for TBW that exceeded body weight in mice. Therefore, body composition was measured in mice using a range of resistance coefficients. Resistance values at 10% of those defined for rats provided TBW, ECFV, and ICFV ratios to body weight that were similar to those obtained by conventional isotope dilution. Further evaluation of the sensitivity of the BIS system was determined by its ability to detect volume changes after saline infusion; saline provided the predicted changes in compartmental fluid volumes. In summary, BIS is a noninvasive and accurate method for the estimation of body composition in mice. The ability to perform serial measurements will be a useful tool for future studies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Estimation of Body Fluid Volume by Bioimpedance Spectroscopy in Patients with Hyponatremia

PURPOSE Estimation of body fluid volume in hyponatremia is useful for diagnosis and therapeutic decision-making. Physical examination has been generally used to estimate body fluid volume, but it depends on the physician's abilities. Bioimpedance spectroscopy has been suggested to be a reliable method for the estimation of body fluid volume. Therefore, this study investigated whether bioimpedan...

متن کامل

Segment-specific resistivity improves body fluid volume estimates from bioimpedance spectroscopy in hemodialysis patients.

Discrepancies in body fluid estimates between segmental bioimpedance spectroscopy (SBIS) and gold-standard methods may be due to the use of a uniform value of tissue resistivity to compute extracellular fluid volume (ECV) and intracellular fluid volume (ICV). Discrepancies may also arise from the exclusion of fluid volumes of hands, feet, neck, and head from measurements due to electrode positi...

متن کامل

Comparison of bioimpedance methods for estimating total body water and intracellular water changes during hemodialysis.

BACKGROUND The accurate assessment of body fluid volume is important in many clinical situations. Hannan et al. proposed a single-frequency bioimpedance equation (HE) to calculate extracellular water (ECW) and total body water (TBW). There are two equations based on the bioimpedance spectroscopy (BIS) method for the evaluation of body fluid volume: Xitron equations (XE) and body composition spe...

متن کامل

Estimation of body composition and normal fluid status using a calf bioimpedance technique.

UNLABELLED The aims of this study in hemodialysis (HD) patients were: 1. To evaluate the relationship of calf bioimpedance with total body composition and fluid status as measured by gold standard methods. 2. To investigate the ability of calf normalized resistivity (CNR) to predict the normal fluid status (dry weight: DW) in a prospective study. In the body composition study (n = 41), fluid st...

متن کامل

Effect of change in fluid distribution in segments in hemodialysis patients at different ultrafiltration rates on accuracy of whole body bioimpedance measurement.

This study explored divergence (error) between ultrafiltration volumes (UFV) and intradialytic changes in extracellular volume (ΔECV) in hemodialysis (HD) patients measured by whole body (wBIS) and sum of segmental bioimpedance spectroscopy (sBIS). The primary aim of the study was to evaluate the effect of different ultrafiltration rates (UFR) on error of estimation of ΔECV by changes in their ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of physiology. Renal physiology

دوره 299 1  شماره 

صفحات  -

تاریخ انتشار 2010