Wavelength-interrogated surface plasmon resonance sensor with mesoporous-silica-film-enhanced sensitivity to small molecules.

نویسندگان

  • Zhe Zhang
  • Dan-feng Lu
  • Qian Liu
  • Zhi-mei Qi
  • Liangbao Yang
  • Jinhuai Liu
چکیده

Sol-gel copolymer-templated mesoporous silica films with a thickness of 70 nm and interpore spacing of 4.34 nm were fabricated on gold layer covered glass substrates for application as a wavelength-interrogated surface plasmon resonance (SPR) sensor. The resonance wavelength (λ(R)) of the sensor with a solution sample was determined by absorptiometry at a given incident angle. A comparison between the experimental data obtained with the coated and uncoated SPR chips demonstrated that the mesoporous silica film effectively enhanced sensor response to individual adsorption of cysteamine molecules and lead(II) ions. An approximate proportional relationship between the resonance-wavelength shift of the sensor and the volume fraction of analyte molecules adsorbed in the mesoporous silica film was obtained by numerical simulation. Porosities of 0.865 and 0.785 for the two silica films used as well as the volume fractions of 0.048 and 0.116 for adsorbed lysozyme and cysteamine molecules were determined by fitting the simulation results to the experimental data. The adsorbed amount of cysteamine (∼0.5 nm) is equivalent to more than 16 full monolayers on the geometric surface of the mesoporous silica film used. In contrast, an equivalence of less than 2 full monolayers for adsorbed lysozyme molecules (3 nm × 3 nm × 4.5 nm) suggests that the mesoporous silica film has good size-selective adsorption capability due to its uniform pore size distribution. Cysteamine modification of the mesoporous silica film renders the SPR sensor able to detect lead(II) ions at concentrations as low as 1 nM.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Nanoporous Gold Films Prepared by a Combination of Sputtering and Dealloying for Trace Detection of Benzo[a]pyrene Based on Surface Plasmon Resonance Spectroscopy

A wavelength-interrogated surface plasmon resonance (SPR) sensor based on a nanoporous gold (NPG) film has been fabricated for the sensitive detection of trace quantities of benzo[a]pyrene (BaP) in water. The large-area uniform NPG film was prepared by a two-step process that includes sputtering deposition of a 60-nm-thick AuAg alloy film on a glass substrate and chemical dealloying of the allo...

متن کامل

Figure of Merit Enhancement of a Surface Plasmon Resonance Sensor Using a Low-Refractive-Index Porous Silica Film

In this paper; the surface plasmon resonance (SPR) sensor with a porous silica film was studied. The effect of the thickness and porosity of the porous silica film on the performance of the sensor was analyzed. The results indicated that the figure of merit (FOM) of an SPR sensor can be enhanced by using a porous silica film with a low-refractive-index. Particularly; the FOM of an SPR sensor wi...

متن کامل

Hydrogen sensing by localized surface plasmon resonance in colloidal solutions of Au-WO3-Pd

Nowadays, hydrogen has attracted significant attention as a next generation clean energy source. Hydrogen is highly flammable, so detection of hydrogen gas is required. Gold nanoparticle based localized surface plasmon resonance (LSPR) is an advanced and powerful sensing technique, which is well known for its high sensitivity to surrounding refractive index change in the local environment. We p...

متن کامل

Optimization of Sensitivity and Stability of Gold/Silver bi-Layer Thin Films Used in Surface Plasmon Resonance Chips

The aim of this study is experimental assay of sensitivity and stability of a bimetallic silver/gold SPR sensor chip. This chip utilizes the sensitivity of the silver and the stability of the gold. Moreover, the Silver layer (instead of usual Cr or Ti layer) was used as an adhesive intermediate layer between the Gold layer and the glass substrate. The optimization of the Gold/Silver thickness u...

متن کامل

Dispersion curve-based sensitivity engineering for enhanced surface plasmon resonance detection

Manipulation of dispersion curve for enhancing surface plasmon resonance (SPR) detection is proposed. Based on strong correlation between slope of dispersion curve and SPR angle shift, it is confirmed that dispersion curve characteristics can be employed as an analysis tool to evaluate SPR sensor performance and to predict anomalous plasmonic behaviors. Complicated resonance shift in SPR angle,...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Analyst

دوره 137 20  شماره 

صفحات  -

تاریخ انتشار 2012