Reproducibility of ultrasonographic measurements of different carotid and femoral artery segments in healthy subjects and in patients with increased intima-media thickness.
نویسندگان
چکیده
1. The reproducibility of measurements of the arterial wall thickness in both the carotid and femoral artery was investigated by means of high-resolution B-mode ultrasonography. For this purpose, subjects with normal and increased intima-media thickness were selected. Images were stored on an optical disk and were analysed with a semi-automatic software program by two readers. Individuals were scanned twice by two independent observers. 2. Measurements were performed of the far and near wall of the common carotid artery and bulbous in 30 healthy subjects and 19 patients known to have an increased intima-media thickness. Far-wall measurements were made of the internal carotid artery on both sides and common femoral artery on the right side only. 3. In healthy subjects the mean within-observer coefficient of variation was 1.8% and 3.0% for the far wall in the common carotid artery on the right side and left side, respectively. For the near wall the mean coefficient of variation of the common carotid artery was 2.8% on the right and 3.4% on the left side. The mean coefficient of variation was less than 4% for both far and near wall in the bulbous and far wall in the internal carotid artery. Even in patients with increased intima-media thickness the mean coefficient of variation of each segment was less than 4.5%. In the control subjects the between-observer coefficient of variation of the common carotid artery was 2.8% and 5.1% for the far wall on the right and left side, respectively, and 3.4% and 4.2% for the near wall on the right and left side. In healthy subjects a mean difference of 0.002 mm within observers was found in the right far-wall common carotid artery, with limits of agreement of -0.048 to 0.052 mm. The coefficient of repeatability was 0.050 mm. For patients with increased intima-media thickness the mean difference in this segment was -0.006 mm (-0.094 to 0.082) with a coefficient of repeatability of 0.088 mm. For the near wall in the common carotid artery and far and near wall in the bulbous and internal carotid artery the mean differences were larger, but were all below 0.1 mm. The differences and limits of agreements increased between observers. In patients the between-observer mean difference of the far wall of the common carotid artery was -0.055 mm (-0.255 to 0.145). For the common femoral artery of normal control subjects the within- and between-observer mean differences were 0.005 mm (-0.119 to 0.129) and 0.015 mm (-0.081 to 0.111), respectively. 4. In conclusion, the reproducibility of intima-media thickness measurements in the common carotid artery is reliable, even in patients with increased artery wall thickness. Also in other segments prone to atherosclerosis, such as the bulbous, internal carotid artery and common femoral artery, a good reproducibility was found. To obtain good reproducibility it is highly recommended to use the same ultrasonographer to scan patients in follow-up studies.
منابع مشابه
Comparison of the Intima-media Thickness of Carotid Artery in Children with Diabetes Type One and Control Group Using Ultrasound
Background & Aims: Diabetes is a very important factor for stroke due to blocked blood vessels. It can involve systemic and cerebrovascular arteries at the same time via microangiopathy and macroangiopathy. This project aimed to compare the intima-media thickness of carotid artery in children with diabetes type and the control group. Methods: In this case-control study, 50 children with the age...
متن کاملCarotid artery Intima-Media thickness and cardiovascular risk factors in chronic hemodialysis patients
Introduction: Common carotid artery intima-media thickness (CCA-IMT) correlates with cardiovascular mortality in patients under hemodialysis. In this investigation, we evaluated relationship between CCA-IMT with dependent and independent cardiovascular risk factors in chronic hemodialysis patients. Methods: In this cross-sectional study, 51 chronic hemodialysis patients, (31 males and 20 fema...
متن کاملارتباط آلوپسی آندروژنتیک در زنان با ضخامت لایـهی اینتیمـا مدیـای سرخـرگ کاروتیـد
Background and Aim: Androgenetic alopecia (AGA) is the most common cause of hair loss after puberty and its association with comorbid diseases including metabolic syndrome and cardiovascular diseases has become well known over the past two decades. The aim of this study was to evaluate the relationship between androgenetic alopecia with carotid artery intima media thickness as a marker for earl...
متن کاملEvidence for in vivo carotid and femoral wall thickening in human hypertension. Groupe de Prévention Cardio-vasculaire en Médecine du Travail.
Little is known of the in vivo structural changes of large arteries in uncomplicated hypertension. Therefore, we measured the intima-media thickness and lumen diameter of common carotid and femoral arteries by a computerized ultrasonographic technique in 25 normotensive and 25 never treated hypertensive men of similar age (from 25 to 72 years). The intraobserver variability of carotid and femor...
متن کاملارتباط آدیپونکتین و نشانگرهای آتروسکلروز پیشبالینی در مبتلایان جدید به دیابت نوع دو: بررسی ضخامت انتیما- میدیای شریان کاروتید و امتیاز کلسیم شریان کرونر
Background: The aim of this study was to assess the association of serum adiponectin and a set of traditional cardiovascular risk factors with carotid artery intimal-medial thickness (CIMT) and coronary artery calcium score (CACS), as markers of subclinical atherosclerosis in subjects with early type 2 diabetes mellitus. Methods: Carotid artery intima- media thickness (measured by B-mode ultrso...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical science
دوره 93 4 شماره
صفحات -
تاریخ انتشار 1997