Improved Analysis of Trace Hormones in Drinking Water by LC/MS/MS (EPA 539) using the Agilent 6460 Triple Quadrupole LC/MS

ثبت نشده
چکیده

A modification to the chromatographic conditions of EPA method 539 has been developed that reduces the total run time by more than a factor of three, while providing complete baseline resolution of all seven hormones and DLs that meet the EPA requirements. Response is 7 to 11 times more sensitive in negative mode compared to the use of ammonium hydroxide, and 1.7 to 2.4 times more sensitive in positive mode. The performance of the Agilent 6460 Triple Quadrupole LC/MS System can be used to determine where problems may be occurring, if labs have trouble in method implementation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Adapting EPA Method 8330B for Analysis of Explosives in Water to SPE and LC/MS/MS Authors

EPA Method 8330B for trace explosives in water by HPLC was transferred from UV detection to mass spectrometry detection using the Agilent 1290 Infinity LC System coupled to the Agilent 6460 Triple Quadrupole LC/MS System using APCI negative mode. Eleven explosive compounds were analyzed with this method at trace concentrations in water samples with limits of detection at the 5–50 ng/L concentra...

متن کامل

Optimizing Detection of Steroids in Wastewaters Using the Agilent 6490 Triple Quadrupole LC/MS System with iFunnel Technology

Taking full advantage of the enhanced sensitivity of the Agilent 6490 Triple Quadrupole LC/MS System requires optimization of method parameters derived on other Triple Quadrupole platforms. Optimization of steroid analysis methods in the complex matrix of wastewater results in sensitivity as low as sub-1 ng/L (1 part per trillion).

متن کامل

Analysis of Potential Genotoxic Arylamine and Aminopyridine Impurities in Active Pharmaceutical Ingredients Agilent 1290 Infinity LC system and Agilent 6460A Triple Quadrupole MS system for method development and fast analysis

This Application Note illustrates the possibilities of the Agilent 1290 Infinity LC system and the Agilent 6460A Triple Quadrupole Mass Spectrometer for quantitative analysis of potential genotoxic impurities (PGIs) in active pharmaceutical ingredients (APIs). A generic approach was used to determine arylamine and aminopyridine PGIs in selected APIs. The influence of column length and mobile ph...

متن کامل

Validation of a Cannabinoid Quantitation Method Using an Agilent 6430 LC/MS/MS Authors

A method was developed and validated for the quantitation of cannabinoids with LC/MS/MS using an Agilent 6430 Triple Quadrupole LC/MS system. Validation showed that the LC/MS/MS method provides reliable results for the quantitation of THC, OH-THC, and carboxy-THC that meet predetermined acceptance criteria [1]. The concentration range of target compounds used in this validation was chosen to fi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013