Thick CZT Detectors for Space-Borne X-ray Astronomy
نویسندگان
چکیده
Cadmium Zinc Telluride (CZT) detectors are having a major impact on the field of hard X-ray astronomy. Without the need for cryogenic cooling they achieve good spatial and energy resolutions over the broad energy range from 10 keV to ∼600 keV. In this paper, we briefly review the historical development of detectors used in Xray astronomy. Subsequently, we present an evaluation of CZT detectors from the company Imarad. The standard 2×2×0.5 cm detectors, contacted with 8×8 In pixels and an In cathode, exhibit FWHM energy resolutions of 7 keV at 59 keV, and 10 keV at 662 keV. A direct measurement of the 662 keV photopeak efficiency gives 67%. We have started a detailed study of the performance of Imarad detectors depending on surface preparation, contact materials, contact deposition, post-deposition detector annealing, and detector passivation techniques. We present first results from contacting detectors with Cr, Ag, Au, and Pt.
منابع مشابه
CZT in Space Based Hard X-ray Astronomy: Background Predictions for EXIST
One of the key aspects of a detector material for space-borne hard X-ray and gamma-ray telescopes is the rate of prompt and delayed background events generated inside the material by charged and neutral particles striking the detector. These particles are Cosmic Rays, particles trapped in Earth’s magnetic field, and secondaries from Cosmic Ray interacting with the atmosphere and the spacecraft....
متن کاملDesign and Testing of a Prototype Pixellated CZT Detector and Shield for Hard X-Ray Astronomy
We report on the design and laboratory testing of a prototype imaging CZT detector intended for balloon flight testing in April 2000. The detector tests several key techniques needed for the construction of large-area CZT arrays, as required for proposed hard X-ray astronomy missions. Two 10 mm × 10 mm × 5 mm CZT detectors, each with a 4 × 4 array of 1.9 mm pixels on a 2.5 mm pitch, will be mou...
متن کاملConstruction and Testing of a Pixellated CZT Detector and Shield for a Hard X-ray Astronomy Balloon Flight
We report on the construction and laboratory testing of pixellated CZT detectors mounted in a flip-chip, tiled fashion and read out by an ASIC, as required for proposed hard X-ray astronomy missions. Two 10 mm × 10 mm × 5 mm detectors were fabricated, one out of standard eV Products high-pressure Bridgman CZT and one out of IMARAD horizontal Bridgman CZT. Each was fashioned with a 4 × 4 array o...
متن کاملBalloon-borne Hard X-ray Imaging and Future Surveys
Several payloads for hard X-ray (20-600 keV) imaging with coded aperture telescopes have been developed for balloon flight observations of cosmic x-ray sources. We briefly review the characteristics of these, particularly the EXITE2 system. The recent NASA program to develop an extended long duration (100d) balloon flight capability employing super-pressure balloons would allow a qualitatively ...
متن کاملCZT imaging detectors for ProtoEXIST
We describe the detector development for a balloon-borne wide-field hard X-ray (20 – 600 keV) telescope, ProtoEXIST. ProtoEXIST is a pathfinder for both technology and science of the proposed implementation of the Black Hole Finder Probe, Energetic X-ray Imaging Survey telescope (EXIST). The principal technology challenge is the development of large area, close-tiled modules of imaging CZT dete...
متن کامل