Anterior capsule staining using 0.025% trypan blue in cataracts without red reflex

نویسندگان

  • Eduardo Ferrari Marback
  • Lincoln Lemes de Freitas
  • Fernanda Pelegrino Fernandes
  • Bruno Castelo Branco
  • Rubens Belfort
چکیده

Purpose: To describe the use of anterior capsule staining in cataracts without red reflex using a 0.025% trypan blue solution. Methods: Six eyes of 6 patients with cataracts without red reflex were submitted to phacoemulsification using a direct injection of 0.2 to 0.5 ml of 0.025% trypan blue in the anterior chamber previous to viscoelastic injection. All patients had an ophthalmologic examination prior to surgery, as well as pre and postoperative corneal endothelial cell count. Results: In all cases the capsule became stained with a faint blue color that enabled an adequate visibility of the flap during the continuous curvilinear anterior capsulotomy (CCC). There were no intra-or postoperative complications. The endothelial cell loss varied between 1.8% and 26.6% (mean 12.8%). Conclusion: Staining the anterior capsule with 0.025% trypan blue solution allows a good visibility of the capsular flap and facilitates the confection of CCC in cataracts without red reflex. Uso de azul tripano a 0,025% para corar a cápsula anterior em catarata sem reflexo

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

[Unintentional staining of lens posterior capsule with trypan blue during extracapsular cataract extraction: case report].

Report of a complication related to the use of 0.1% trypan blue during capsular staining of the anterior crystalline lens capsule in an extracapsular cataract extraction with intraocular lens implantation. The capsular dye was injected using an air-bubble technique, inadvertently, it was done using high pressure dispersing the dye through the zonules leading to a complete lost of red reflex, th...

متن کامل

Cystoid macular oedema with trypan blue use.

We present a large comparative series of trypan blue use in cataract surgery. This series of trypan blue used in all eyes regardless of cataract severity may be unique. We found an apparent increased rate of cystoid macular oedema (CMO) associated with trypan blue use. Melles et al’s report on the use of trypan blue in cataract extraction in 1999 combined with Apple et al’s series on dye enhanc...

متن کامل

Under-air staining of the anterior capsule using Trypan blue with a 30 G needle

The original technique of staining the anterior capsule of the lens with Trypan blue involves the injection of an air bubble in the anterior chamber. A drawback of this technique is the possible instability of the anterior chamber caused by the sudden exit of air when the dye is injected with the cannula through the side-port incision. Other staining techniques that use viscoelastic substances ...

متن کامل

Inadvertent Trypan Blue Staining of Posterior Capsule during Cataract Surgery Associated with "Argentinian Flag" Event.

Trypan blue is common in visualizing the anterior capsule during cataract surgery. Inadvertent staining of the posterior capsule during phacoemulsification is a rare complication and there are few reports in the literature. The proposed mechanism of posterior capsule staining in previous reports includes a compromised zonular apparatus or iris retractors facilitating the posterior flow of trypa...

متن کامل

New technique to demonstrate corneal magnification using trypan blue in cataract surgery Nova técnica para demonstrar a magnificação corneana utilizando azul de tripan na cirurgia de catarata

Purpose: To demonstrate the corneal magnification using trypan blue in cataract surgery. Methods: Eight eyes of eight patients undergoing phacoemulsification with an intraocular lens implantation were enrolled in this study. After staining the anterior capsule with Trypan Blue 0.1% and performing the capsulorhexis, the excised anterior capsule was placed on the corneal surface. By observing and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002