Automated clean-up, separation and detection of polycyclic aromatic hydrocarbons in particulate matter extracts using a 2D-LC/2D-GC system: a method translation from two FIDs to two MS detectors

نویسندگان

  • Hwanmi Lim
  • Trifa M. Ahmed
  • Christoffer Bergvall
  • Roger Westerholm
چکیده

An online two-dimensional (2D) liquid chromatography/2D gas chromatography system with two mass-selective detectors has been developed on the basis of a previous system with two flame ionization detectors. The method translation involved the change of carrier gas from hydrogen to helium, column dimension and detectors. The 2D system with two mass-selective detectors was validated with use of polycyclic aromatic hydrocarbon (PAH) standards and two standard reference materials from air and diesel exhaust. Furthermore, the system was applied to a real sample, wood smoke particulates. The PAH values determined correlated well with the previous data and those from the National Institute of Standards and Technology. The system enhanced the benefits of the previous system, which were limited by the low detectability and lack of mass selectivity. This study shows an automated 2D system that is valid for PAH analysis of complex environmental samples directly from crude extracts. Graphical Abstract Schematic illustration showing on-line clean-up, separation and detection using 2D-LC/2D-GC/MS.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of Polycyclic Aromatic Hydrocarbons in Ambient Urban Air

Polycyclic aromatic hydrocarbons (PAHS) have been determined in the atmosphere of Isfahan, Iran. Airborne particulate matter was sampled using a high-volume air sampler at roof-top level (~6m). Extraction of PAHS from airborne particulate matter has been performed using SFE system and the relationship between the extraction temperature and the recovery of PAHS</su...

متن کامل

Quantification of complex polycyclic aromatic hydrocarbon mixtures in standard reference materials using comprehensive two-dimensional gas chromatography with time-of-flight mass spectrometry.

This research is the first to quantify complex PAH mixtures in NIST SRMs using comprehensive two-dimensional gas chromatography coupled to time-of-flight mass spectrometry (GC×GC/ToF-MS), with and without extract cleanup, and reports previously unidentified PAH congeners in the NIST SRMs. We tested a novel, high orthogonality GC column combination (LC-50×NSP-35), as well as with a commonly used...

متن کامل

Optimized method for determination of 16 FDA polycyclic aromatic hydrocarbons (PAHs) in mainstream cigarette smoke by gas chromatography–mass spectrometry

A gas chromatography-mass spectrometry (GC-MS) method was validated for the determination of 16 polycyclic aromatic hydrocarbons (PAHs) from the FDA list of 93 harmful or potentially harmful constituents of mainstream cigarette smoke (MCS). Target analytes were extracted from total particulate matter using accelerated solvent extraction with a toluene/ethanol solvent mixture. Matrix artefacts w...

متن کامل

Determination of oxygenated and native polycyclic aromatic hydrocarbons in urban dust and diesel particulate matter standard reference materials using pressurized liquid extraction and LC–GC/MS

The objective of this study was to develop a novel analytical chemistry method, comprised of a coupled high-performance liquid chromatography-gas chromatography/mass spectrometry system (LC-GC/MS) with low detection limits and high selectivity, for the identification and determination of oxygenated polycyclic aromatic hydrocarbons (OPAHs) and polycyclic aromatic hydrocarbons (PAHs) in urban air...

متن کامل

Determination of Some Polycyclic Aromatic Hydrocarbons in the Caspian Seawater by HPLC Following Preconcentration with Solid-Phase Extraction

A solid-phase extraction (SPE) method for sample clean-up and preconcentration followed by reversed-phase high-performance liquid chromatography (RP-HPLC) with uv detection is reported for determination of polycyclic aromatic hydrocarbons (PAHs) in the caspian seawater. A good resolution was obtained using acetonitrile:water (40:60) as mobile-phase for separation of these compounds. The eff...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 409  شماره 

صفحات  -

تاریخ انتشار 2017