Use of a single coil transvenous electrode with an abdominally placed implantable cardioverter defibrillator in children.
نویسندگان
چکیده
While transvenous defibrillator electrode placement avoiding a thoracotomy is preferable, electrode size, a large intercoil spacing, and the need for subclavicular device placement preclude this approach in most children. We investigated a single RV coil to an abdominally placed active can ICD device. Five children ages 8-16 years (weight 21-50 kg, mean 35 kg) underwent ICD placement. Placement of a single coil Medtronic model 6932 or 6943 electrode was performed via the left subclavian vein approach and the electrode positioned in the RV apex with the coil lying along the RV diaphragmatic surface. The ICD (Medtronic Micro Jewel II model 7223 Cx) was implanted in a left abdominal pocket with the lead tunneled from the infraclavicular region to the pocket. Implant DFTs were < or = 15 J using a biphasic waveform. DFTs rechecked within 3-month postimplant were unchanged. Lead impedance at implant ranged from 38 to 56 omega, mean 51 omega. Follow-up was 3-21 months (total 82 months) with no electrode dislodgment, lead fractures, or inappropriate discharges. Two of the five patients have had successful appropriate ICD discharges. Transvenous ICD electrode placement can be performed in children as small as 20 kg with the device implanted in a cosmetically acceptable abdominal pocket that is well tolerated. Excellent DFTs can be achieved. This approach avoids a thoracotomy in all but the smallest child, does not require subclavicular placement of the device, and avoids use of a second intravascular coil.
منابع مشابه
Implantable cardioverter-defibrillator in a patient with dextrocardia situs inversus
Background: Dextrocardia is a congenital anomaly, which may have coexistent coronary artery disease (CAD), arrhythmias and conventional indications for device therapy. However, the implantation of transvenous leads can be technically challenging and the approach needs to be tailored to the patient's individual anatomy. Case presentation: A 54-year-old male with dextrocardia situs inversus and i...
متن کاملSuperior Vena Cava Electrode
Background A unipolar defibrillation system using a single right ventricular (RV) electrode and the active shell or "CAN" of the implantable cardioverter-defibrillator itself situated in a left infraclavicular pocket has been shown to be as efficient in defibrillation as an epicardial lead system. The purpose of this study was to determine whether defibrillation efficacy can be improved further...
متن کاملTHE EFFECT OF NURSE-PEER-LED SUPPORT INTERVENTION ON QUALITY OF LIFE IN PATIENTS WITH AN IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR: A RANDOMIZED CLINICAL TRIAL
Background & Aims: Nowadays, the quality of life and how coping and treatment of patients with an implantable cardiac defibrillator has led to concern and attempts to reduce or eliminate the problems of these patients in the people who provide health care services. This study aimed to determine the effect of nurse-peer-led support intervention on quality of life in patients with an implantable ...
متن کاملIntrapericardial Implantation of an Implantable Cardioverter-Defibrillator in a Child
Implantable cardioverter defibrillator (ICD) can be a crucial therapeutic modality for pediatric patients with congenital heart disease, Brugada syndrome, long QT syndrome and cardiomyopathy. Because transvenous implantation of ICD is mostly unfeasible for pediatric patients due to anatomical and technical limitations, epicardial patch type or subcutaneous type ICD have been used. Implantation ...
متن کاملMinimally invasive, pericardial implantable cardioverter-defibrillator placement in a young child
We report the successful minimally invasive placement of a pericardial implantable cardioverter-defibrillator (ICD) in a 16-kg child. A transvenous ICD dual coil was advanced through a small subxiphoid incision and screwed into the oblique sinus pericardium under fluoroscopic guidance. An additional sense-pace lead was sutured onto the right ventricular apex, and the generator was placed in the...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Pacing and clinical electrophysiology : PACE
دوره 23 5 شماره
صفحات -
تاریخ انتشار 2000