Attenuation coefficient determination of printed ABS and PLA samples in diagnostic radiology standard beams
نویسندگان
چکیده
IAEA code of practice TRS-457 states that standard phantoms should offer the same primary attenuation and scatter production as relevant body section of a representative patient. Material cost, availability and dimensional stability must also be considered. The goal of this study is to determine the attenuation coefficient of printed ABS and PLA in standard X-ray beams, verifying if phantoms printed with these materials could be an easier-handle substitute for PMMA, enabling the creation of different designs in an easier and cheaper way. Results show that PMMA presents higher attenuation coefficient, followed by PLA and ABS, which means that thinner PMMA layer creates higher radiation attenuation.
منابع مشابه
Study of PLA Printability with Flexography Ink: Comparison with Common Packaging Polymer
Today, the economic consumption of biodegradable polymers is of capital importance in many applications. One of the most commonly used biopolymers is polylactic acid (PLA). The printability of the biodegradable film has not been fully investigated. This work tested the printability of polylactic acid (PLA) films and compared the print qualities to common packaging films like low density pol...
متن کاملDetermination of the attenuation coefficient for megavoltage photons in the water phantom
Background: Attenuation coefficient (μ) plays an important role in calculations of treatment planning systems, as well as determination of dose distributions in external beam therapy, dosimetry, protection, phantom materials and industry. So, its exact measurement or calculation is very important. The aim of this study was to evaluate the μ in different points in the water phantom anal...
متن کاملAn Analytical-empirical Calculation of Linear Attenuation Coefficient of Megavoltage Photon Beams
Background: In this study, a method for linear attenuation coefficient calculation was introduced.Methods: Linear attenuation coefficient was calculated with a new method that base on the physics of interaction of photon with matter, mathematical calculation and x-ray spectrum consideration. The calculation was done for Cerrobend as a common radiotherapy modifier and Mercury.Results: The values...
متن کاملAn iterative method to estimate x-ray attenuation coefficients in computed tomography
Introduction: The basis of image formation in Computed Tomography (CT) lies in the x-ray linear attenuation coefficient of the scanned material. Compton scattering and photoelectric effect are the dominant interactions of the x-ray photons with the subject, in the range of diagnostic radiology. These two coefficients are important in tissue characterization by Dual-Energy CT (D...
متن کاملAssessment of the Radiation Attenuation Properties of Several Lead Free Composites by Monte Carlo Simulation
Background:In diagnostic radiology lead apron, are usually used to protect patients and radiology staff against ionizing radiation. Lead apron is a desirable shield due to high absorption and effective attenuation of x-ray photons in the diagnostic radiology range.Objective: Although lead aprons have good radiation protection properties, in recent years, researchers have been looking for altern...
متن کامل