Cone-beam computed tomography analysis of the apical third of curved roots after mechanical preparation with different automated systems.
نویسندگان
چکیده
The present study evaluated by cone-beam computed tomography (CBCT) the apical canal transportation and centralizing ability of different automated systems after root canal preparation. The mesiobuccal canals of maxillary first molars (n=10 per group) were prepared with: GI - reciprocating system with K-Flexofile; GII - reciprocating system with NiTiFlex files; GIII - rotary system with K3 instruments; GIV - rotary system with RaCe instruments. CBCT scans were taken before and after biomechanical preparation up to a #40.02 diameter. Canal transportation was determined by measuring the smallest distance between the inner canal walls and the mesial and distal sides of the root. The centralization ability corresponded to the difference between the measurements from transportation evaluation, using the linear voxel to voxel method of analysis. The mean transportation was 0.06 + or - 0.14 mm, with a tendency to deviate to the mesial side of the root (n=22), with no statistically significant difference among the groups (p=0.4153). The mean centralization index was 0.15 + or - 0.65 also without statistically significant difference among the groups (p=0.0881). It may be concluded that apical canal transportation and centralization ability were not influenced by the type of mechanical movement and instruments used.
منابع مشابه
An Ex vivo Analysis of Apical Transportation in Root Canals Prepared with BT Race Rotary and Hand K-Flexofile by Cone Beam Computed Tomography
Background and purpose: The purpose of mechanical cleaning of the root canal is to clean the canal walls, create a conical shape to facilitate access, effective washing, and filling all areas of the root canal. Errors such as root canal transportation are cuased by excessive dentin removal from the canal. The objective of this study was to investigate root canal transportation by a BT Race rota...
متن کاملCentering and transportation: in vitro evaluation of continuous and reciprocating systems in curved root canals
CONTEXT One of the goals of endodontic therapy is the shaping and cleaning of the root canal system. In recent years, there has been multiple systems instrumentation, and changes in their dynamics are central to maintain the original shape of the canal after preparation. AIMS The aim of this study was to evaluate centering and transportation in curved root canals after using ProTaper(®) and M...
متن کاملEvaluation of Canal Transportation and Centering Ability of Safesider and K-Flexofile: Using Cone-beam Computed Tomography
Abstract Background and aim: Maintaining the original geometry of canal is an important parameter in successful root canal treatment. The aim of this original study was evaluation of apical root canal transportation and centering ability of SafeSider and K-Flexofile using cone beam computed tomography. Materials and Methods: Mesiobuccal root canals of maxillary first molars, with 20-40° curvatu...
متن کاملComparison of Canal Transportation, Centering Ratio by Cone-beam Computed Tomography after Preparation with Different File Systems.
AIM One Shape Apical 1 (OSA 1) is a new file for preparing the apical aspect of the root canal after One Shape (OS, Micro Mega, Besançon, France). This study compared apical transportation and centering ratios in curved root canals, which were instrumented with ProTaper Next (PTN, Dentsply Tulsa Dental Specialties, Tulsa, OK) up to size X3 and with OS up to OSA 1. MATERIALS AND METHODS Forty-...
متن کاملInvestigating Root Canal Number and Morphology of Mandibular Anterior Teeth Using Cone Beam Computed Tomography
Background and purpose: Root therapy will be successful if it is done based on a correct diagnosis and appropriate treatment plan with the knowledge of morphology and tooth anatomy, debridement, disinfection, and obturation of the entire root canal system. This study aimed to investigate the number and morphology of canals in root canals mandibular anterior using cone beam computed tomography (...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Brazilian dental journal
دوره 20 5 شماره
صفحات -
تاریخ انتشار 2009