Comparison of intraocular lens power calculation methods in eyes that have undergone laser-assisted in-situ keratomileusis.

نویسندگان

  • Li Wang
  • Marc A Booth
  • Douglas D Koch
چکیده

PURPOSE To compare methods of calculating intraocular lens (IOL) power for cataract surgery in eyes that have undergone myopic laser-assisted in-situ keratomileusis (LASIK). METHODS Eleven eyes of eight patients who had previously undergone myopic LASIK (amount of LASIK correction, -5.50 +/- 2.61 D (SD); range, -8.78 to -2.38 D) and subsequently phacoemulsification with implantation of the SA60AT IOLs were included (refractive error after cataract surgery, -0.61 +/- 0.79 D; range, -2.0 to 1.0 D). We evaluated the accuracy of various combinations of (1) single-K versus double-K (in which pre-LASIK keratometry is used to estimate effective lens position) versions of the IOL formulas; the Feiz-Mannis method was also evaluated; (2) four methods for calculating corneal refractive power (clinical history, contact lens overrefraction, adjusted EffRP (EffRP(adj)), and Maloney methods); and (3) four IOL formulas (SRK/T, Hoffer Q, Holladay 1, and Holladay 2). The IOL prediction error was obtained by subtracting the IOL power calculated using various methods from the power of the implanted IOL, and the F test for variances was performed to assess the consistency of the prediction performance by different methods. RESULTS Compared to double-K formulas, single-K formulas predicted lower IOL powers than the power implanted and would have left patients hyperopic in the majority of the cases; the Feiz-Mannis method had the largest variance. For the Hoffer Q and Holladay 1 formulas, the variances for EffRP(adj) were significantly smaller than those for the clinical history method (0.43 D2 vs 1.74 D2, P = .018 for Hoffer Q; 0.75 D2 vs 2.35 D2, P = .043 for Holladay 1). The Maloney method consistently underestimated the IOL power but had significantly smaller variances (0.19 to 0.55 D2) than those for the clinical history method (1.09 to 2.35 D2) (P < .015). There were no significant differences among the variances for the four formulas when using each corneal power calculation method. CONCLUSIONS The most accurate method was the combination of a double-K formula and corneal values derived from EffRP(adj). The variances in IOL prediction error were smaller with the Maloney and EffRP(adj) methods, and we propose a modified Maloney method and second method using Humphrey data for further evaluation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Orbscan II-assisted intraocular lens power calculation for cataract surgery following myopic laser in situ keratomileusis (an American Ophthalmological Society thesis).

PURPOSE This study tests the hypothesis that the keratometric value derived from Orbscan II mean power maps, when used in an intraocular lens (IOL) calculation formula, at a specific measurement zone, will accurately determine the power of an IOL for planned cataract surgery in patients who have undergone prior myopic laser-assisted in situ keratomileusis (LASIK). METHODS This is a two-part s...

متن کامل

No-history method of intraocular lens power calculation for cataract surgery after myopic laser in situ keratomileusis.

PURPOSE To prospectively evaluate the no-history method for intraocular lens (IOL) power calculation in 15 cataractous eyes that had previous myopic laser in situ keratomileusis (LASIK) and for which the pre-LASIK K-readings were not available. SETTING Private practice, Lynwood, California, USA. METHODS The predicted IOL power was calculated in each case. Also calculated were the mean arith...

متن کامل

Prediction accuracy of intraocular lens power calculation methods after laser refractive surgery

BACKGROUND This study aimed to evaluate the prediction accuracy of postoperative refractions using partial coherence interferometry (IOL-Master) and applanation ultrasound (AL-3000) assisted with corneal topography (TMS-4) in eyes that had undergone myopic laser-assisted in situ keratomileusis (LASIK). METHODS Haigis-L formula, Koch-Maloney method using Haigis formula, Shammas clinically deri...

متن کامل

Olsen Formula

By Thomas Olsen, MD, PhD The calculation of IOL power in an eye that has undergone corneal refractive surgery is not a straightforward task. However, if you understand why the calculation may go wrong, you will have a fair chance of getting a good result using modern technology. It is important to understand that the calculation errors of post-LASIK eyes are the sum of the traditional errors pl...

متن کامل

[Intraocular lens power calculations in eyes with previous corneal refractive surgery].

Results of intraocular lens power calculation were lower than actual required power in eyes with previous corneal refractive surgery because the inaccurate readings of corneal power obtained from standard keratometry. This causes the unacceptable hyperopia after cataract surgery. With increasing of population undergone excimer laser refractive surgery, this problem will be an obvious problem in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Transactions of the American Ophthalmological Society

دوره 102  شماره 

صفحات  -

تاریخ انتشار 2004