Fast high-resolution magnetic resonance imaging demonstrates fractality of myocardial perfusion in microscopic dimensions.

نویسندگان

  • W R Bauer
  • K H Hiller
  • P Galuppo
  • S Neubauer
  • J Köpke
  • A Haase
  • C Waller
  • G Ertl
چکیده

The fractal nature of heterogeneity of myocardial blood flow and its implications for the healthy and diseased heart is not yet understood. The main hindrance for investigation of blood flow heterogeneity and its role in physiology and pathophysiology is that conventional methods for determination of myocardial perfusion have severe limitations concerning temporal and spatial resolution and invasiveness. In isolated rat hearts, we developed a nuclear magnetic resonance technique that does not depend on contrast agents and in which the apparent longitudinal relaxation time is made perfusion sensitive by selective preparation of the imaging slice. This perfusion-sensitive relaxation time is determined within 40 seconds as a map with a high spatial in-plane resolution of 140x140 microm(2) and a thickness of 1.5 mm. Perfusion imaging was validated with the established microsphere technique. Additionally, the congruence between perfusion-sensitive T:(1) maps and first-pass perfusion imaging was demonstrated. As an application of high-resolution perfusion imaging, fractal analysis of the spatial distribution of perfusion was performed. We were able to demonstrate that the fractality of this distribution exists even in microscopic dimensions. Vasodilation by nitroglycerin modulated the fractal pattern of perfusion, and the decrease of the fractal dimension indicated a shift toward homogeneity. This implies that parameters of the fractal distribution depend on the microvascular tone rather than on anatomic preformations; ie, fractality is a functional characteristic of perfusion.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A quantitative high resolution assessment of myocardial blood flow from contrast-enhanced first-pass magnetic resonance perfusion imaging: microsphere validation in a magnetic resonance compatible free beating explanted pig heart model

A quantitative high resolution assessment of myocardial blood flow from contrast-enhanced first-pass magnetic resonance perfusion imaging: microsphere validation in a magnetic resonance compatible free beating explanted pig heart model Andreas Schuster, Matthew Sinclair, Niloufar Zarinabad, Masaki Ishida, Jeroen P van den Wijngaard, Matthias Paul, Pepijn van Horssen, Shazia T Hussain, Divaka Pe...

متن کامل

Performance of myocardial perfusion imaging using multi-focus fan beam collimator with resolution recovery reconstruction in a comparison with conventional SPECT

  Objective: IQSPECT is an advanced high-speed SPECT modality for performing myocardial perfusion imaging (MPI), which uses a multi-focus fan beam collimator with resolution recovery reconstruction. The aim of this study was to compare IQSPECT compared with conventional SPECT interms of performance based on standard clinical protocols. In addition, we examined the concordance between convention...

متن کامل

Effect of Improving Spatial or Temporal Resolution on Image Quality and Quantitative Perfusion Assessment with k-t SENSE Acceleration in First-Pass CMR Myocardial Perfusion Imaging

k-t Sensitivity-encoded (k-t SENSE) acceleration has been used to improve spatial resolution, temporal resolution, and slice coverage in first-pass cardiac magnetic resonance myocardial perfusion imaging. This study compares the effect of investing the speed-up afforded by k-t SENSE acceleration in spatial or temporal resolution. Ten healthy volunteers underwent adenosine stress myocardial perf...

متن کامل

High spatial and temporal myocardial CINE T2* mapping at 7.0 T: a feasibility study

Background Myocardial tissue characterization using T2* relaxation mapping techniques is an emerging application of clinical cardiovascular magnetic resonance imaging. The increase in microscopic susceptibility at higher magnetic field strengths renders myocardial T2* mapping at ultrahigh magnetic fields conceptually appealing. This work demonstrates the feasibility of myocardial T2* imaging at...

متن کامل

mR myocardial Perfusion imaging1

Otavio R. Coelho-Filho, MD, MPH Carsten Rickers, MD Raymond Y. Kwong, MD, MPH Michael Jerosch-Herold, PhD Contrast material–enhanced myocardial perfusion imaging by using cardiac magnetic resonance (MR) imaging has, during the past decade, evolved into an accurate technique for diagnosing coronary artery disease, with excellent prognostic value. Advantages such as high spatial resolution; absen...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation research

دوره 88 3  شماره 

صفحات  -

تاریخ انتشار 2001