LCDG 4 and DigiSim – Simulation activities at NICADD / NIU
نویسنده
چکیده
We present two software packages developed to support detector R&D studies for the International Linear Collider. LCDG4 is a full-detector simulator that provides energy deposits from particles traversing the sensitive volumes of the detector. It has been extensively used within the American ILC community, providing data for algorithm development and detector optimization studies. DigiSim models real-life digitization effects, converting the idealized response into simulated detector readout. It has many useful features to improve the realism in modeling detector response. The main characteristics of these two complementary packages are discussed.
منابع مشابه
Multiscale electrochemistry of hydrogels embedding conductive nanotubes† †Electronic supplementary information (ESI) available: Alginate/carbon nanotube bead fabrication and optical image, SECM approach curves in benzonitrile, 2D conductivity images, SECM of the tip penetrating inside the bead and Digisim® simulation of cyclic voltammograms obtained at an UME inside a 1% CNT bead. See DOI: 10.1039/c5sc00549c Click here for additional data file.
متن کامل
A New Stochastic Framework for Accurate Lung Segmentation
New techniques for more accurate unsupervised segmentation of lung tissues from Low Dose Computed Tomography (LDCT) are proposed. In this paper we describe LDCT images and desired maps of regions (lung and the other chest tissues) by a joint Markov-Gibbs random field model (MGRF) of independent image signals and interdependent region labels but focus on most accurate model identification. To be...
متن کاملThe Ucla/nicadd Plasma Density Transition Trapping Experiment∗
Plasma density transition trapping is a recently purposed self-injection scheme for plasma wake-field accelerators. This technique uses a sharp downward plasma density transition to trap and accelerate background plasma electrons in a plasma wake-field. Two and three dimensional Particle-In-Cell (PIC) simulations show that electron beams of substantial charge can be captured using this techniqu...
متن کاملA Framework for Unsupervised Segmentation of Lung Tissues from Low Dose Computed Tomography Images
New techniques for more accurate unsupervised segmentation of lung tissues from Low Dose Computed Tomography (LDCT) are proposed. In this paper we describe LDCT images and desired maps of regions (lung and the other chest tissues) by a joint Markov-Gibbs random field model (MGRF) of independent image signals and interdependent region labels but focus on most accurate model identification. To be...
متن کاملStatus of the UCLA/NICADD Plasma Density Transition Trapping Experiment
Plasma density transition trapping is a recently proposed self-injection scheme for plasma wake-field accelerators. This technique uses a sharp downward plasma density transition to trap and accelerate background plasma electrons in a plasma wake-field. This paper recounts the first attempt to demonstrate density transition trapping experimentally. The goal of the experiment is to capture a ∼ 1...
متن کامل