(3)he-MRI-based measurements of intrapulmonary p(O2) and its time course during apnea in healthy volunteers: first results, reproducibility, and technical limitations.
نویسندگان
چکیده
We applied a recently developed method of following the time course of the intrapulmonary oxygen partial pressure p(O2)(t) during apnea by (3)He MRI to healthy volunteers. Using two imaging series with different interscan times during two breathholds (double acquisition technique), relaxation of (3)He due to paramagnetic oxygen and depolarization by RF pulses were discriminated. In all four subjects, the temporal evolution of p(O2) was found to be linear, and was described by an initial partial pressure p(0) and a decrease rate R. Also, regional differences of both p(0) and R were observed. A correlation between p(0) and R was apparent. Finally, we discuss limitations of the double acquisition approach.
منابع مشابه
THE EFFECT OF ARTERIAL O2 SATURATION AND HE ART RATE ON BLOOD PRESSURE DURING HYPOXIA
A periodic increase in blood pressure (BP) occurs during apneic episodes in patients with obstructive sleep apnea (OSA). Several factors including hypoxemia and an increase in heart rate (HR) were reported to be responsible for this increased BP. To examine the contribution of these two factors in increasing BP, 35 healthy male subjects (mean age±SD= 23.64±3.80) were studied in three experi...
متن کاملThe Utilization of Web-based Continuing Medical Education Courses in Mashhad University of Medical Sciences and its Relationship with Course Characteristics
Introduction: One of the educational methods which can overcome time and distance limitations is electronic learning. Healthcare professionals, facing with such limitations, also need continuing education to keep their information up to date. This study was conducted to evaluate the utilization of electronic courses by the medical professionals in Mashhad University of Medical Sciences and its ...
متن کاملبررسی نتایج درمان لامینکتومی بر اساس نمای مورفولوژیک MRI
Abstract Background: To study the outcomes of patients diagnosed with lumbar spinal stenosis undergoing Laminectomy based on the morphology of the dural sac on magnetic resonance images. Materials and methods: Patients diagnosed with lumbar spinal stenosis who were candidates for Laminectomy entered this case series study. The morphology of the dural sac on MRI and preoperative Oswestry Di...
متن کاملAssessment of Reproducibility of Geometric Distortion in MRI using Phantom Measurements
Introduction: Image distortion is one of the major problems of magnetic resonance imaging (MRI) for use in 3DMRI, velocity MRI, FMRI and radiotherapy treatment planning (RTTP). It is widely known that the most obvious effect of the inhomogenity of the magnetic fields and the nonlinearity of the gradient is the Geometric Distortion of MR tomograms. In this study, the...
متن کاملReproducibility and accuracy of optic nerve sheath diameter assessment using ultrasound compared to magnetic resonance imaging
BACKGROUND Quantification of the optic nerve sheath diameter (ONSD) by transbulbar sonography is a promising non-invasive technique for the detection of altered intracranial pressure. In order to establish this method as follow-up tool in diseases with intracranial hyper- or hypotension scan-rescan reproducibility and accuracy need to be systematically investigated. METHODS The right ONSD of ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- NMR in biomedicine
دوره 13 4 شماره
صفحات -
تاریخ انتشار 2000