CT-Angiography–Based Evaluation of the Aortic Annulus for Prosthesis Sizing in Transcatheter Aortic Valve Implantation (TAVI)–Predictive Value and Optimal Thresholds for Major Anatomic Parameters

نویسندگان

  • Florian Schwarz
  • Philipp Lange
  • Dominik Zinsser
  • Martin Greif
  • Peter Boekstegers
  • Christoph Schmitz
  • Maximilian F. Reiser
  • Christian Kupatt
  • Hans C. Becker
چکیده

BACKGROUND/OBJECTIVES To evaluate the predictive value of CT-derived measurements of the aortic annulus for prosthesis sizing in transcatheter aortic valve implantation (TAVI) and to calculate optimal cutoff values for the selection of various prosthesis sizes. METHODS The local IRB waived approval for this single-center retrospective analysis. Of 441 consecutive TAVI-patients, 90 were excluded (death within 30 days: 13; more than mild aortic regurgitation: 10; other reasons: 67). In the remaining 351 patients, the CoreValve (Medtronic) and the Edwards Sapien XT valve (Edwards Lifesciences) were implanted in 235 and 116 patients. Optimal prosthesis size was determined during TAVI by inflation of a balloon catheter at the aortic annulus. All patients had undergone CT-angiography of the heart or body trunk prior to TAVI. Using these datasets, the diameter of the long and short axis as well as the circumference and the area of the aortic annulus were measured. Multi-Class Receiver-Operator-Curve analyses were used to determine the predictive value of all variables and to define optimal cutoff-values. RESULTS Differences between patients who underwent implantation of the small, medium or large prosthesis were significant for all except the large vs. medium CoreValve (all p's<0.05). Furthermore, mean diameter, annulus area and circumference had equally high predictive value for prosthesis size for both manufacturers (multi-class AUC's: 0.80, 0.88, 0.91, 0.88, 0.88, 0.89). Using the calculated optimal cutoff-values, prosthesis size is predicted correctly in 85% of cases. CONCLUSION CT-based aortic root measurements permit excellent prediction of the prosthesis size considered optimal during TAVI.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

SCCT expert consensus document on computed tomography imaging before transcatheter aortic valve implantation (TAVI)/transcatheter aortic valve replacement (TAVR).

Computed tomography (CT) plays an important role in the workup of patients who are candidates for implantation of a catheter-based aortic valve, a procedure referred to as transcatheter aortic valve implantation (TAVI) or transcatheter aortic valve replacement (TAVR). Contrast-enhanced CT imaging provides information on the suitability of the peripheral access vessels to accommodate the relativ...

متن کامل

Two-dimensional transesophageal echocardiography for aortic annular sizing in patients undergoing transcatheter aortic valve implantation.

BACKGROUND Accurate preoperative assessment of the aortic annulus dimension is crucial for successful transcatheter aortic valve implantation (TAVI). In this study we examined the accuracy of a novel method using two-dimensional transesophageal echocardiography (2D-TEE) for measurement of the aortic annulus. METHODS We evaluated the theoretical impact of the measurement of the annulus diamete...

متن کامل

Prognostic value of the ratio between prosthesis area and indexed annulus area measured by MultiSlice-CT for transcatheter aortic valve implantation procedures

BACKGROUND Postprocedural aortic regurgitations following transcatheter aortic valve implantation (TAVI) procedures remain an issue. Benefit of oversizing strategies to prevent them isn't well established. We compared different level of oversizing in our cohort of consecutive patients to address if severe oversizing compared to normal sizing had an impact on post-procedural outcomes. METHODS ...

متن کامل

Transcatheter aortic valve implantation: role of multi-detector row computed tomography to evaluate prosthesis positioning and deployment in relation to valve function.

AIMS Aortic regurgitation after transcatheter aortic valve implantation (TAVI) is one of the most frequent complications. However, the underlying mechanisms of this complication remain unclear. The present evaluation studied the anatomic and morphological features of the aortic valve annulus that may predict aortic regurgitation after TAVI. METHODS AND RESULTS In 53 patients with severe aorti...

متن کامل

Feasibility of a new method using two-dimensional transesophageal echocardiography for aortic annular sizing in patients undergoing transcatheter aortic valve implantation; a case–control study

BACKGROUND Accurate preoperative assessment of the aortic annulus dimension is crucial for successful transcatheter aortic valve implantation (TAVI). In this study we validated a new method using two-dimensional transesophageal echocardiography (2D-TEE) for measurement of the aortic annulus prior to TAVI. METHODS We analysed 124 patients who underwent successful TAVI using a self-expandable p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2014