Precision Calculation of Bhabha Scattering at Lep

نویسندگان

  • S. JADACH
  • M. MELLES
  • B. F. L. WARD
چکیده

For the small-angle Bhabha-scattering process, we consider the error budget for the calculation of the LEP/SLC luminosity in the Monte Carlo event generator BHLUMI 4.04, from the standpoint of new calculations of exact results for the respective O(α 2) photonic corrections in the context of the Yennie-Frautchi-Suura exponentiation. We find that an overall precision tag for the currently available program BHLUMI 4.04 can be reduced from 0.11% to 0.061% at LEP1 and from 0.25% to 0.122% at LEP2. For the large-angle Bhabha process, we present the Monte Carlo program BHWIDE and compare its predictions with predictions of other Monte Carlo programs as well as semi-analytical calculations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigation of vacuum polarization in t-channel radiative Bhabha scattering

We discuss the possibility of a precision measurement of vacuum polarization in t-channel radiative Bhabha scattering at a high luminosity collider. For illustration, the achievable precision is estimated for the BaBar experiment at PEP-II and for the OPAL experiment at LEP.

متن کامل

0 v 1 8 O ct 1 99 9 Event generation of large - angle Bhabha scattering at LEP 2 energies

LABSMC Monte Carlo event generator is used to simulate Bhabha scattering at high energies. Different sources of radiative corrections are considered. The resulting precision is discussed.

متن کامل

X iv : h ep - p h / 98 11 43 6 v 1 2 3 N ov 1 99 8 Light Pair Correction to Bhabha Scattering at Small Angle

This work deals with the computation of electron pair correction to small angle Bhabha scattering, in order to contribute to the improvement of luminometry precision at lep/slc below 0.1% theoretical accuracy. The exact qed four-fermion matrix element for e + e − → e + e − e + e − , including all diagrams and mass terms, is computed and different Feynman graph topologies are studied to quantify...

متن کامل

Light Pair Correction to Bhabha Scattering at Small Angle

This work deals with the computation of electron pair correction to small angle Bhabha scattering, in order to contribute to the improvement of luminometry precision at lep/slc below 0.1% theoretical accuracy. The exact qed four-fermion matrix element for e+e− → e+e−e+e−, including all diagrams and mass terms, is computed and different Feynman graph topologies are studied to quantify the error ...

متن کامل

Performance of the Opal Si-w Luminometer at Lep I-ii

The LEP ee collider at CERN operated for more than a decade: in 198995 at center of mass energies close to the Z peak (LEP-I); in 1996-2000 at higher energies, up to 209 GeV (LEP-II). In the first phase a large number of Z events were collected, of the order of 5 × 10 events per experiment. To match the inherent precision of this data sample, the error on the integrated luminosity had to be bet...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1999