A double Gerdien instrument for simultaneous bipolar air conductivity measurements on balloon platforms.
نویسندگان
چکیده
A bipolar air conductivity instrument is described for use with a standard disposable meteorological radiosonde package. It is intended to provide electrical measurements at cloud boundaries, where the ratio of the bipolar air conductivities is affected by the presence of charged particles. The sensors are two identical Gerdien-type electrodes, which, through a voltage decay method, measure positive and negative air conductivities simultaneously. Voltage decay provides a thermally stable approach and a novel low current leakage electrometer switch is described which initiates the decay sequence. The radiosonde supplies power and telemetry, as well as measuring simultaneous meteorological data. A test flight using a tethered balloon determined positive (sigma(+)) and negative (sigma(-)) conductivities of sigma(+)=2.77+/-0.2 fS m(-1) and sigma(-)=2.82+/-0.2 fS m(-1), respectively, at 400 m aloft, with sigma(+)sigma(-)=0.98+/-0.04.
منابع مشابه
A Novel Technique to Determine Atmospheric Ion Mobility Spectra
Detailed tropospheric ion measurements are needed to improve understanding of the electrical microphysics affecting clouds. Additionally, atmospheric ion mobility spectra can be used to identify ion growth processes leading to condensation nucleus formation. However these measurements are rare, particularly in the troposphere where the majority of clouds form. Developments in the operating theo...
متن کاملWhat we can learn from measurements of air electric conductivity in 222Rn-rich atmosphere
Electric conductivity of air is an important characteristic of the electric properties of an atmosphere. Testing instruments to measure electric conductivity ranging from ~10 to 10Sm in natural conditions found in the Earth atmosphere is not an easy task. One possibility is to use stratospheric balloon flights; another (and a simpler one) is to look for terrestrial environments with significant...
متن کاملMeasurement of Upper Air Pressure, Temperature and Humidity
12.1.1 Definitions The following definitions from WMO (1992; 2003a) are relevant to upper air measurements using a radiosonde: Radiosonde: Instrument intended to be carried by a balloon through the atmosphere, equipped with devices to measure one or several meteorological variables (pressure, temperature, humidity, etc.), and provided with a radio transmitter for sending this information to the...
متن کاملDaily variations of indoor air-ion and radon concentrations.
Air-ions and radon are two atmospheric trace constituents which have two opposite effects on human health: the ions are beneficial, and radon gas is potentially lethal as it increases the risk of lung cancer. In the lower troposphere, radon is the most important generator of the air-ions. Ionization by cosmic rays and radioactive minerals is almost constant in daily cycles, and variation of air...
متن کاملConsideration of accurate dose distribution for Contura balloon catheter in breast brachytherapy with MCNP5 simulation
Introduction: Contura is a balloon applicator that used to deliver intra cavity radiation for Partial Breast Irradiation (PBI) treatments. Contura with 4 peripheral lumens surrounding the central, for loading HDR sources from an after loader system can provide an asymmetric dose distribution and gives a more flexible shape of dose than earlier balloon applicators such as Mammo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Review of scientific instruments
دوره 79 8 شماره
صفحات -
تاریخ انتشار 2008