Progressive functional deterioration of bioprostheses assessed by Doppler ultrasonography.
نویسندگان
چکیده
Doppler echocardiography was used to study the function of bioprosthetic heart valves by noninvasive means in 32 patients aged 29 to 72 years at various postoperative intervals. There were 24 Ionescu-Shiley, four Hancock, and four Carpentier-Edwards prostheses, 19 in the aortic and 13 in the mitral position. Initial studies were performed at a mean of 2.3 years after implantation and were repeated one, two, and three years thereafter. Flow velocities in the mitral orifice, left ventricular outflow tract, and ascending aorta, as well as mitral pressure half-time, were measured from pulsed-wave or continuous-wave Doppler recordings. Mitral and aortic valve areas and aortic pressure gradients were calculated. In aortic prostheses the valve area decreased and pressure gradient increased progressively in relation to the time from implantation. The mean value (+/- SD) of the aortic valve area was 67 +/- 17 percent of the manufacturer's nominal value at the first examination and 57 +/- 20 percent one year later, 51 +/- 14 percent two years later, and 46 +/- 11 percent three years later (overall differences, p less than 0.01). In mitral prostheses, reduction of the valve area was not related to the time from implantation. The mean mitral valve area was 45 +/- 12 percent of the nominal value at rest and increased to 68 +/- 18 percent during exercise at a mean of 45 months after implantation. There was no change in these values at the one-year repeat study. It is concluded that in a population with predominantly pericardial bioprostheses, (1) aortic tissue prostheses showed a progressive functional deterioration demonstrable by Doppler echocardiography, most probably due to degenerative changes; and (2) in mitral tissue prostheses, there was no significant reduction of orifice area in relation to time from implantation. Reduction of mitral valve areas may, to some extent, reflect a less than full opening at rest.
منابع مشابه
Non-invasive assessment by Doppler ultrasound of 155 patients with bioprosthetic valves: a comparison of the Wessex porcine, low profile Ionescu-Shiley, and Hancock pericardial bioprostheses.
One hundred and fifty five patients with 167 bioprosthetic valves (68 Wessex porcine, 54 Hancock pericardial, and 45 low profile Ionescu-Shiley pericardial valves) were studied by Doppler ultrasound. Valve gradients were calculated from the mitral and aortic flow velocities by the modified Bernoulli equation. Mean mitral gradients were significantly smaller across the Ionescu-Shiley valves than...
متن کاملReproducibility of functional transcranial Doppler sonography in determining hemispheric language lateralization.
BACKGROUND AND PURPOSE Since functional transcranial Doppler ultrasonography (fTCD) allows convenient and fully automated quantification of language lateralization, it seems ideal for longitudinal studies of perfusion changes during deterioration as well as recovery of language functions. However, during serial examinations, the technical, stochastic, and physiological variabilities of cerebral...
متن کاملThree-dimensional Power Doppler Ultrasonographic Evaluation of Induced Cystitis in Dogs
Objectives: The aim of this study was to investigate if three-dimensional power Doppler (3DPD) ultrasound (US) can detect bacterial cystitis in dogs better than two-dimensional (2D) US. Animals: Six mixed breed dogs Procedures: Ten ml of 0.1% alcoholic solution of salicylic acid was entered into the urinary bladder of six male mixed-breed dogs by catheter. Twenty four hours later, culture sol...
متن کاملبررسی نقش یافته های داپلر سونوگرافی در تعیین شانس تعبیه ، میزان شکست و قابل دستیابی شدن فیستول شریانی وریدی در بیماران همودیالیزی کاندید تعبیه فیستول شریانی وریدی
Background: Arteriovenous fistula is an important method for hemodialysis and prediction of fistula function and failure rate and access is crucial. This study was performed to determine the association between Doppler ultrasonography findings with function and failure and access rate of fistula. Methods: In this observational comparative cross-sectional study, out of 108 patients requiring fi...
متن کاملLong-term Doppler echocardiographic results of aortic or mitral valve replacement with Biocor porcine bioprosthesis.
OBJECTIVES Our objectives were to evaluate the long-term bioprosthetic and cardiac functional outcome after insertion (over a 10-year period) of a new-generation porcine zero pressure-fixed Biocor bioprosthesis, as well as to determine the echocardiographic accuracy for selection of patients requiring reoperation. The long-term systematic Doppler echocardiographic assessment after valve replace...