A comparative study on the accuracies exhibited by four commonly used interocclusal registration materials
نویسندگان
چکیده
Interocclusal records are an everyday necessity in routine prosthodontic practice. A number of materials have been advocated by several groups of workers over a length of time to be suitable for the purpose. In the present study, the accuracies exhibited by four commonly used interocclusal recording materials were compared when they were subjected to both the clinical and laboratory phases of jaw relation transfers. The four materials were Zinc oxide and eugenol impression paste, wax corrected with Zinc oxide and eugenol impression paste, Impression plaster and medium body hydrophilic Vinyl Polysiloxane impression material. The results revealed that Vinyl Polysiloxane impression material was the most accurate and clinically acceptable for the purpose. All other materials were found to have significant levels of variance from the control. All four materials exhibited statistically significant variances among the records produced by each one of them and at the various occlusal regions considered. Further scopes still exist to increase the domain of the study and include the other materials found to be suitable for making interocclusal registrations.
منابع مشابه
Comparison of the accuracy and dimensional stability of interocclusal recording materials - An in- vitro study
Purpose: The purpose of this in vitro study was to compare and correlate the accuracy and dimensional stability of commonly used interocclusal recording materials. Materials and methods: A stainless steel die, made according to modified ADA specification no. 19, was loaded with different interocclusal recording materials. These materials were separated from die 3 min after their respective sett...
متن کاملComparative Evaluation of the Accuracy and Dimensional Stability of Three Interocclusal Recording Materials- An In Vitro Study
AIMS: To compare accuracy and dimensional stability of 3 inter occlusal recording materials , as a function of time. Method of study 3 commercially available inter occlusal recording materials investigated in this study were chemically bite registration wax, bis acrylic and polyvinylsiloxane. A mold of ADA specification no 19 was used. Samples of 10 specimen each were made. Specimen were disc s...
متن کاملA comparative evaluation of dimensional stability of three types of interocclusal recording materials-an in-vitro multi-centre study
BACKGROUND The introduction of different interocclusal recording materials has put clinicians in dilemma that which material should be used in routine clinical practice for precise recording and transferring of accurate existing occlusal records for articulation of patient's diagnostic or working casts in the fabrication of good satisfactory prosthesis. In the era of developing world of dentist...
متن کاملEvaluation and Comparison of Resistance to Compression of Various Interocclusal Recording Media: An In Vitro Study
BACKGROUND This in vitro study was conducted to compare the compression resistance of various interocclusal recording materials when subjected to a compressive load. MATERIALS AND METHODS Each interocclusal recording material was manipulated according to the manufacturer instruction and placed into a metallic cylinder. A total of 20 specimens for each interocclusal recording material were mad...
متن کاملA Study on Robustness of Various Deformable Image Registration Algorithms on Image Reconstruction Using 4DCT Thoracic Images
Background: Medical image interpolation is recently introduced as a helpful tool to obtain further information via initial available images taken by tomography systems. To do this, deformable image registration algorithms are mainly utilized to perform image interpolation using tomography images.Materials and Methods: In this work, 4DCT thoracic images of five real patients provided by DI...