Coil protection using small helical coils for wide-neck intracranial aneurysms: a novel approach.
نویسندگان
چکیده
BACKGROUND AND PURPOSE A number of remodeling or protective techniques available to treat wide-neck intracranial aneurysms are increasingly being used, provided that the shape/type of aneurysm, vessel diameter, and inherent course of the vessel are conducive to their use. The purpose of this study was to describe a novel method using coil protection for treatment of wide-neck aneurysms. MATERIALS AND METHODS This technique involves sequential maneuvers to the aneurysm and affected branch artery. A microcatheter is first introduced into the aneurysmal sac, and another microcatheter is introduced into the entrance of the branch artery, followed by partial deployment of a small helical coil into the branch artery. A framing coil is then placed within the aneurysmal sac, under the protection of the helical coil. After completion of the first coil insertion, the helical coil should be retrieved to confirm the stability of the framing coil. The helical coil can also serve as a filler. RESULTS This technique was successfully applied to 12 intracranial saccular aneurysms of the MCA bifurcation (5 patients); anterior communicating artery (3 patients); and A1 and M1 segments, distal ACA, and basilar tip (1 patient each). Selective endovascular treatment was successfully performed and resulted in excellent outcomes in all patients. There were no complications directly related to coil protection. CONCLUSIONS Our small study suggests that coil protection can be a safe alternative to traditional remodeling or protective techniques when those techniques have failed or are not possible due to vascular geometry. It is particularly suited for the treatment of wide-neck aneurysms arising from small and acutely angulated branching vessels.
منابع مشابه
Three-dimensional packing with complex orbit coils for the endovascular treatment of intracranial aneurysms.
BACKGROUND AND PURPOSE Endovascular treatment of intracranial aneurysms is too often associated with aneurysm recurrence due to coil compaction. High packing of coils prevents compaction. To increase the packing attenuation, we sought to evaluate the results of selective embolization of aneurysms with complex-shaped coils alone. METHODS Twenty consecutive patients with an intracranial aneurys...
متن کاملEndosaccular treatment of intracranial aneurysms using matrix coils: early experience and midterm follow-up.
BACKGROUND AND PURPOSE The authors report their experience using Matrix coils in the treatment of cerebral aneurysms. METHODS The outcomes of 72 consecutive patients (76 aneurysms) who underwent coiling using Matrix coils at our institution were retrospectively analyzed. RESULTS Seventy-four aneurysms in 70 patients were coiled using Matrix coils (ranging 3% to 100% by coil length; mean 68....
متن کاملEndovascular Management of the Wide-neck Aneurysms: the Applications of the Coils and Catheter
aneurysms has become an accepted treatment option worldwide (1). However, principal disadvantage of embolization of aneurysms with detachable coils is that embolization could be limited by unfavorable shape of the aneurysms (2-5). Coils packed into the lumen of the wide-neck aneurysms have the inherent difficulty that coils can herniate into the parent vessels. The wide-neck of aneurysms also u...
متن کاملSelective endovascular treatment of intracranial aneurysms with sapphire coils.
BACKGROUND AND PURPOSE Endovascular treatment with detachable coils is an accepted alternative to surgical clip placement for intracranial aneurysms. The purpose of this study was to evaluate the safety and reliability of the Sapphire coil, a new platinum coil for the treatment of intracranial aneurysms. METHODS Between August and September 2003, 20 consecutive patients (13 women, seven men; ...
متن کاملEmbolization of intracranial aneurysms with Guglielmi detachable coils augmented by microballoons.
We describe two cases in which balloons were used to aid in the occlusion of intracranial aneurysms with Guglielmi detachable coils. In both patients, initial attempts to place coils within the aneurysmal sac failed, as the loops of the coil repeatedly protruded through a wide aneurysmal neck into the parent vessel. Temporary balloons placed across the neck of these small, wide-necked aneurysms...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 34 1 شماره
صفحات -
تاریخ انتشار 2013