Comparison of recovery rates for mycobacteria from BACTEC 12B vials, Middlebrook 7H11-selective 7H11 biplates, and Lowenstein Jensen slants in a public health mycobacteriology laboratory.

نویسندگان

  • M L Wilson
  • B L Stone
  • M V Hildred
  • R R Reves
چکیده

Recovery rates from Middlebrook 7H11-selective 7H11 biplates and Lowenstein-Jensen slants (LJ) used with BACTEC 12B vials were compared for 5,399 specimens. For 578 specimens that were inoculated onto three media, 580 mycobacteria were isolated, including 277 (48%) Mycobacterium avium complex isolates, 230 (40%) Mycobacterium tuberculosis isolates, and 73 (12%) other mycobacteria. For BACTEC 12B vials, 506 (87%) cultures were positive, 45 (8%) were negative, and 29 (5%) were lost to contamination; for 7H11-7H11-selective biplates, 469 (81%) cultures were positive, 95 (16%) were negative, and 16 (3%) were lost to contamination; for LJ, 230 (40%) cultures were positive, 111 (19%) were negative, and 239 (41%) were lost to contamination. For routine cultures, use of plate media is superior to use of LJ.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Role of solid media when used in conjunction with the BACTEC system for mycobacterial isolation and identification.

This study evaluated the necessity and the contribution of solid media when used in conjunction with radiometric Middlebrook 7H12 (BACTEC 12B; Becton Dickinson, Towson, Md.) medium for recovery and complete identification of mycobacteria. Each of 1,184 digested, decontaminated respiratory specimens was inoculated into one BACTEC 12B vial, one 7H11 plate, and two Lowenstein-Jensen (LJ) slants. W...

متن کامل

Multicenter evaluation of the BACTEC MGIT 960 system for recovery of mycobacteria.

We evaluated the BACTEC MGIT 960 system, which is a fully automated, noninvasive system for the growth and detection of mycobacteria with a capacity to incubate and continuously monitor 960 7-ml culture tubes. We studied 3,330 specimens, 2,210 respiratory and 1,120 nonrespiratory specimens, collected from 2,346 patients treated at six sites. Processed specimens were inoculated into the BACTEC M...

متن کامل

Comparison of the BACTEC MGIT 960 and ESP culture system II for growth and detection of mycobacteria.

The performances of two continuously monitoring mycobacterial culture systems-ESP Culture System II (ESP II; Trek Diagnostics, Inc. , Westlake, Ohio) and BACTEC MGIT 960 (BD Biosciences, Sparks, Md. )-were compared. In addition to both liquid media, all specimens were plated onto Middlebrook 7H11/7H11 selective agar. A total of 3, 151 specimens of all types (56.3% were respiratory specimens) we...

متن کامل

Rapid diagnosis of pulmonary tuberculosis

INTRODUCTION World Health Organization had estimated 9.4 million tuberculosis cases on 2009, with 1.7 million of deaths as consequence of treatment and diagnosis failures. Improving diagnostic methods for the rapid and timely detection of tuberculosis patients is critical to control the disease. The aim of this study was evaluating the accuracy of the cord factor detection on the solid medium M...

متن کامل

Optimum recovery of Mycobacterium avium complex from blood specimens of human immunodeficiency virus-positive patients by using small volumes of isolator concentrate inoculated into BACTEC 12B bottles.

Recovery of Mycobacterium avium complex organisms from 412 lysis-centrifugation (Isolator) concentrates of blood specimens obtained from human immunodeficiency virus-positive individuals was attempted with the following media (and Isolator concentrate inoculum volumes): BACTEC 12B broth (0.2 and 1.0 ml), Lowenstein-Jensen slants (0.1 ml), and Middlebrook 7H10/11 agar (0.1 ml). A total of 42 M. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 33 9  شماره 

صفحات  -

تاریخ انتشار 1995