Validated RP-HPLC and TLC methods for simultaneous estimation of tamsulosin hydrochloride and finasteride in combined dosage forms.
نویسندگان
چکیده
Reversed-phase high-performance liquid chromatography (RP-HPLC) and thin-layer chromatography (TLC) methods have been developed and validated for simultaneous estimation of tamsulosin hydrochloride and finasteride in bulk drug and in combined dosage forms. RP-HPLC separation was achieved on a Phenomenex C18 column using methanol/0.02 mol L-1 ammonium acetate buffer/triethylamine (79.9 + 20 + 0.1, V/V/V) (pH 9.2) as mobile phase. TLC separation was achieved on an aluminium-backed layer of silica gel 60 F254 using toluene/methanol/triethylamine (9 + 1.5 + 1, V/V/V) as eluent. Quantification was achieved with photodiode array (PDA) detection at 235 nm over the concentration range 0.5-16 and 1-50 μg mL-1 with mean recovery of 99.8 ± 0.9 and 100.0 ± 0.8% for tamsulosin hydrochloride and finasteride, respectively, by the RP-HPLC method. Quantification was achieved with UV detection at 270 nm over the concentration range 100-2000 ng per spot and 250-5000 ng per spot with mean recovery of 98.9 ± 0.9 and 99.6 ± 0.7 % for tamsulosin hydrochloride and finasteride, respectively, by the TLC method. Both methods are simple, precise, accurate and sensitive and are applicable to the simultaneous determination of tamsulosin hydrochloride and finasteride in bulk drug and in combined dosage forms.
منابع مشابه
Analytical Method Development & Validation for Simultaneous Determination of Dutasteride and Tamsulosin in Bulk as Well as in Pharmaceutical Dosage Form by Using Rp-hplc
Objective: The present work was undertaken with the aim to develop and validate a rapid and consistent RP-HPLC method in which the peaks will be appear with short period of time as per ICH Guidelines. Methods: The proposed method was simple, fast, accurate and precise method for the Quantification of drug in the dosage form, bulk drug as well as for routine analysis in Quality control. Reversed...
متن کاملStability Indicating Rp-hplc Method Development & Validation for Simultaneous Determination of Dutasteride and Tamsulosin in Bulk as Well as in Pharmaceutical Dosage Form by Using Pda Detector
Objective: The present work was undertaken with the aim to develop and validate a rapid and consistent stability indicating RP-HPLC in which the peaks will be appear with short period of time as per ICH Guidelines. The proposed method was simple, fast, accurate and precise method for the Quantification of drug in the dosage form, bulk drug as well as for routine analysis in Quality control. Met...
متن کاملA New Stability Indicating RP-HPLC Method Development and Validation for the Simultaneous Estimation of Dolutegravir and Rilpivirine in Bulk and its Dosage Forms
A New Stability Indicating RP-HPLC Method Development and Validation for the Simultaneous Estimation of Dolutegravir and Rilpivirine in Bulk and its Dosage Forms. Abstract The objective of the work is to develop and validate a new, simple, highly sensitive, stability indicating RP-HPLC method for simultaneous estimation of Dolutegravir and Rilpivirine in bulk and its dosage f...
متن کاملApplication of hydrotropic solubilization in spectrophotometric analysis of Esomeprazole and Itopride pharmaceutical combined tablet dosage forms
Two simple, accurate and precise methods for simultaneous estimation of Esomeprazole and Itopride in bulk drug and tablet dosage form have been described. Method-A employs formation and solving of simultaneous equation using 231 and 370 nm as two analytical wavelengths. Method -B is Absorption ratio method, which uses 308 and 331 nm as two analytical wavelengths.Beer’s law was obeyed in the con...
متن کاملSimultaneous estimation of amlodipine besylate and nebivolol hydrochloride in pharmaceutical tablets formulation by RP-HPLC using PDA detector
Background: The present work was undertaken with the aim to develop and validate a rapid and consistent RP-HPLC method in which the peaks will be appear with short period of time as per ICH Guidelines. Materials and Methods: The separation was achieved on a a stainless steel analytical column, Eclipse XDB plus C18 column (4.6 X 150 mm; 5 μm) in an isocratic mode. The mobile phase w...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Acta pharmaceutica
دوره 60 2 شماره
صفحات -
تاریخ انتشار 2010