Providing newborn resuscitation at the mother’s bedside: assessing the safety, usability and acceptability of a mobile trolley

نویسندگان

  • Margaret R Thomas
  • Charles W Yoxall
  • Andrew D Weeks
  • Lelia Duley
چکیده

BACKGROUND Deferring cord clamping at very preterm births may be beneficial for babies. However, deferring cord clamping should not mean that newborn resuscitation is deferred. Providing initial care at birth at the mother's bedside would allow parents to be present during resuscitation, and would potentially allow initial care to be given with the cord intact. The aim of this study was to evaluate the usability of a new mobile trolley for providing newborn resuscitation by describing the range of resuscitation procedures performed on a group of babies, to assess the acceptability to clinicians compared with standard equipment, based on a questionnaire survey, to assess safety from post resuscitation temperature measurements and serious adverse event reports and to assess whether the trolley allowed resuscitation with the umbilical cord intact by assessing the proportion of babies that could be placed on the trolley to allow resuscitation with the cord intact. METHODS The trolley was used when the attendance of a clinician trained in newborn life support was required at a birth. Clinicians were asked to complete a questionnaire about their experience of using the trolley. Serious adverse events were reported. RESULTS 78 babies were managed on the trolley. Median (range) gestation was 34 weeks (24 to 41 weeks). Median (range) birth weight was 2470 grams (520 to 4080 grams). The full range of resuscitation procedures has been successfully provided, although only one baby required emergency umbilical venous catheterisation. 77/78 babies had a post resuscitation temperature above 36°C. There were no adverse events. Most clinicians rated the trolley as 'the same', 'better' or 'much better' than conventional resuscitation equipment. In most situations, the baby could be resuscitated with umbilical cord intact, although on 18 occasions the cord was too short to reach the trolley. CONCLUSIONS Immediate stabilisation at birth and resuscitation can be performed successfully and safely at the bedside using this trolley. In most cases this could be achieved with an intact umbilical cord.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Innovation in immediate neonatal care: development of the Bedside Assessment, Stabilisation and Initial Cardiorespiratory Support (BASICS) trolley

OBJECTIVE Babies receive oxygen through their umbilical cord while in the uterus and for a few minutes after birth. Currently, if the baby is not breathing well at birth, the cord is cut so as to transfer the newborn to a resuscitation unit. We sought to develop a mobile resuscitation trolley on which newly born babies can be resuscitated while still receiving oxygenated blood and the 'placenta...

متن کامل

Providing immediate neonatal care and resuscitation at birth beside the mother: clinicians’ views, a qualitative study

OBJECTIVES The aims of this study were to assess clinicians' views and experiences of providing immediate neonatal care at birth beside the mother, and of using a mobile trolley designed to facilitate this bedside care. DESIGN Qualitative interview study with semistructured interviews. RESULTS The results were analysed using thematic analysis. SETTING A large UK maternity unit. PARTICIP...

متن کامل

Providing immediate neonatal care and resuscitation at birth beside the mother: parents’ views, a qualitative study

OBJECTIVES The aims of this study were to assess parents' views of immediate neonatal care and resuscitation at birth being provided beside the mother, and their experiences of a mobile trolley designed to facilitate this bedside care. DESIGN Qualitative study with semistructured interviews. Results were analysed using thematic analysis. SETTING Large UK maternity hospital. PARTICIPANTS M...

متن کامل

Motherside care of the term neonate at birth

The rationale for keeping the mother and her newborn together even when neonatal resuscitation is required is presented. The development of a customised mobile resuscitation trolley is detailed explaining how the resuscitation team can be provided with all the facilities of a standard resuscitation trolley to resuscitate the neonate at the mother's side with an intact cord. Alternative low tech...

متن کامل

Evaluation of usability and discomfort of safety footwear in different industries of Mazandaran province

Introduction: Providing safety for human resources in the industry is of great importance and safety shoes are one of the most common PPEs that have the task of protecting the foot against potential hazards. The purpose of this study was to evaluate the discomfort and usability of safety shoes in different industries in order to find gaps in the quality of design and improve the design of safe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2014