چکیده

BACKGROUND A noninvasive system for determining left ventricular (LV) filling pressure may help to improve personalized fluid removal goals in hemodialysis patients. We previously showed that the change in photoplethysmography (PPG) pulse amplitude measured by finger PPG during a Valsalva maneuver correlates with invasively measured left ventricular end-diastolic pressure (LVEDP). This key PPG change, the ratio of finger PPG pulse amplitude at end-Valsalva to baseline, is known as the Pulse Amplitude Ratio, PAR. The objective of this study was to determine how PAR changes after fluid removal in hemodialysis. METHODS We tested subjects with end-stage renal disease, before and after hemodialysis. Each subject performed a Valsalva maneuver with an effort of 20 mmHg for 10 s, guided by the device display. Finger PPG was recorded continuously before and during the maneuver. PAR was calculated automatically. RESULTS Twenty-seven subjects (21 Males) ages 25-75 years were tested. Access sites were AV-fistulas of the arm predominantly. Weight decreased from 99.7 ± 36.9 kg to 97.0 ± 6.0 kg (p < 0.0003) with an average fluid removal of 3.07 ± 1.08 l. Correspondingly, PAR decreased from 0.74 ± 0.24 to 0.62 ± 0.23 (p = 0.003). The change in PAR was correlated with baseline PAR (r = 0.48, p = 0.01). CONCLUSION An index of left heart filling pressure obtained noninvasively using finger photoplethysmography during the Valsalva maneuver is sensitive enough to detect reductions in filling pressure after fluid removal with hemodialysis. Further studies are warranted to determine if this method can be used to guide fluid removal during hemodialysis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Finger photoplethysmography during the Valsalva maneuver reflects left ventricular filling pressure.

It is often challenging to assess cardiac filling pressure clinically. An improved system for detecting or ruling out elevated cardiac filling pressure may help reduce hospitalizations for heart failure. The blood pressure response to the Valsalva maneuver reflects left heart filling pressure, but its underuse clinically may be due in part to lack of continuous blood pressure recording along wi...

متن کامل

Hemodynamic responses during and after multiple sets of stretching exercises performed with and without the Valsalva maneuver

OBJECTIVE This study investigated the acute hemodynamic responses to multiple sets of passive stretching exercises performed with and without the Valsalva maneuver. METHODS Fifteen healthy men aged 21 to 29 years with poor flexibility performed stretching protocols comprising 10 sets of maximal passive unilateral hip flexion, sustained for 30 seconds with equal intervals between sets. Protoco...

متن کامل

Comparison of the effectiveness of tourniquet and Valsalva maneuver in relieving pain caused by propofol injection to induce general anesthesia: A double-blind randomized clinical trial

Introduction: Propofol is one of the most common anesthetic drugs. Painful injection with a reported prevalence of 28 to 90% in various studies is one of the problems of taking Propofol. The present study investigated the effect of performing the Valsalva maneuver and tourniquet twisting on pain intensity and hemodynamic changes. Materials and Methods: This clinical trial was performed on 105 p...

متن کامل

Influence of the Valsalva maneuver on cardiac hemodynamics and right to left shunt in patients with patent foramen ovale

The purpose of this study was to investigate the influence of the Valsalva maneuver (VM) on cardiac hemodynamics in patients with patent foramen ovale (PFO). Sixty-five patients who were highly suspected to have PFO were included. The changes in E, A, E/A ratio of mitral valve blood flow, E, A, E/A ratio of tricuspid valve blood flow, left ventricular end-diastolic volume, area and right atrial...

متن کامل

Pulse pressure response to the strain of the valsalva maneuver in humans with preserved systolic function.

Arterial pulse pressure response during the strain phase of the Valsalva maneuver has been proposed as a clinical tool for the diagnosis of left heart failure, whereas responses of subjects with preserved systolic function have been poorly documented. We studied the relationship between the aortic pulse amplitude ratio (i.e., minimum/maximum pulse pressure) during the strain phase of the Valsal...

متن کامل