Time to take the gloves off: the use of radiation reduction gloves can greatly increase patient dose

نویسندگان

  • Alexander S. Pasciak
  • A. Kyle Jones
چکیده

Sterile radiation reduction gloves have been widely used over the past several decades in an effort to reduce hand doses during fluoroscopically guided proce- dures. While multiple studies have quantified the potential dose reduction to the fluoroscope operator from the use of such gloves, possible effects on the patient have not yet been quantified. The aim of this study was to examine the impact on patient dose when radiation reduction gloves are used. The impact on patient dose when using radiation reduction gloves in the field of view (FOV) was evalu- ated by measuring patient entrance surface dose rates (ESDR) using three C-arm fluoroscopes for a range of patient sizes and different operating and magnification modes. Multiple measuring fields were used in combination with both peripheral and central glove placement. ESDR were measured with no glove in the FOV, with one radiation reduction glove, and with double gloves in the FOV, to replicate the actions of some fluoroscope operators. Compared to an ungloved hand, the use of a single radiation reduction glove in the measuring field resulted in up to a 2.8-fold increase in ESDR. The use of double radiation reduction gloves resulted in up to a 4.9-fold increase in ESDR. In both cases, the increase in ESDR was dependent on the size of the patient and on the operating and magnification modes used, and ranged from no increase up to the aforementioned maximum. When used in the FOV, and particularly within the measuring field, radiation reduction gloves can substantially increase ESDR. This increase in dose, when considered against the relatively small published reduction in dose to the operator's hands, may mean that the increased risks from the use of radiation reduction gloves outweigh the benefits. In any case, hands should not be placed in the FOV if not required by the goals of the procedure. 

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Radiation dose of caregivers could be reduced in thyroid carcinoma patients requiring high dose of radioactive iodine: A case report

Undesired radiation exposure to caregivers is an important problem in radioiodine therapy in thyroid carcinoma patients, especially when patient is non-ambulatory. Special precautions are needed to keep the exposure to caregivers low when higher dose of radioiodine is necessary. Here we present a case-report of a 74-year old male patient with papillary thyroid carcinoma with local invasion and...

متن کامل

مقایسه تأثیر استفاده از دستکش لاتکس و نیتریل بر مهارت دست در جمعیت ایرانی

Introduction: Manual dexterity impairment due to wearing latex and nitrile gloves among health care employees and laboratory personnel can be a remarkable problem because of its adverse outcomes. The present study was conducted to “compare the effect of using latex and nitrile laboratory gloves on hand dexterity”. .Material and Method: In a semi experimental study design, 30 university were s...

متن کامل

Evaluation of Factors Affecting Absorbed Dose, Optimization Methods and Patient Dose Reduction in Dental Cone Beam CT (CBCT)

Introduction: Nowadays the use of cone beam computed tomography in dental imaging is increasing, although this method has a much lower dose than conventional CT scans, it delivers a higher dose than the panoramic and periapical patients therefore, , the aim of this study was to investigate the factors affecting the patients' dose in dental CBCTs and methods of optimizing and reducing the patien...

متن کامل

Assessment of dose reduction and influence of gantry rotation time in CT abdomen examinations

Background: Worldwide the computed tomography (CT) scanning is recognized as a high radiation dose modality. This article aimed to estimate the radiation dose reduction and radiogenic risks for adult patients undertaking abdominal CT examinations. Materials and Methods: A total of 128 patients were studied using 2, 4, 16 and 64 slice CT scanners. The patients were divided into two categories: t...

متن کامل

CT fluoroscopy shielding: decreases in scattered radiation for the patient and operator.

PURPOSE High-radiation exposure occurs during computed tomographic (CT) fluoroscopy. Patient and operator doses during thoracic and abdominal interventional procedures were studied in the present experiment, and a novel shielding device to reduce exposure to the patient and operator was evaluated. MATERIALS AND METHODS With a 16-slice CT scanner in CT fluoroscopy mode (120 kVp, 30 mA), surfac...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2014