Coronary evaginations and peri-scaffold aneurysms following implantation of bioresorbable scaffolds: incidence, outcome, and optical coherence tomography analysis of possible mechanisms.

نویسندگان

  • Tommaso Gori
  • Thomas Jansen
  • Melissa Weissner
  • Nicolas Foin
  • Philip Wenzel
  • Eberhard Schulz
  • Stephane Cook
  • Thomas Münzel
چکیده

BACKGROUND Peri-stent coronary evaginations may disturb flow and have been proposed as possible risk factor for late stent thrombosis. We describe incidence, predictors, and possible mechanisms of coronary evaginations 12 months after implantation of bioresorbable vascular scaffolds (BVS). METHODS AND RESULTS One hundred and two BVS implanted in 90 patients (age 63 ± 13 years, 71 males, 14 diabetics) were analysed with angiography and optical coherence tomography (OCT) 12 months after implantation. Evaginations were identified as any hollow in the luminal vessel contour between well-apposed struts and were classified as major when extending ≥3 mm with a depth ≥10% of the BVS diameter. Fifty-five (54%) of the BVS (50(56%) of the patients) had at least one evagination (6.1 ± 6.2 evaginations per BVS), with a mean volume of 1.9 ± 1.9 mm(3). Major evaginations were only found in one patient, and in-BVS aneurysms in three patients (4BVS). The presence of evaginations was strongly associated with that of malapposition (P = 0.003) and strut fractures (P = 0.01). No association could be shown between the presence and volume of the evaginations and any clinical variable or the presence of uncovered struts (P > 0.5). Peri-strut low-intensity areas (PSLIA) were present in 29 (53%) of the BVS with evaginations and 12 (26%) of those without (P = 0.0049); their presence was independently associated with the presence, the number (P < 0.003) and volume of the evaginations (P = 0.004) and with that of strut fracture. CONCLUSIONS Optical coherence tomography-detected evaginations are relatively common after BVS implantation, but, as for modern drug-eluting metallic stents, major evaginations are very rare. Optical coherence tomography evidence of immature neointima and strut fractures were associated with more severe development of evaginations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Casting light on coronary evaginations: different mechanisms in different coronary devices?

Stent thrombosis (ST) remains a major concern due to high morbidity and mortality in both the short and long term. Although the rates of this complication have been reduced with newer generation drug-eluting stents (DES), the risk of ST continues to persist for all DES and was recently also reported in bioresorbable vascular scaffolds (BVS). – 4 Among the suggested causes of ST are incomplete n...

متن کامل

Optical Coherence Tomography Findings in Bioresorbable Vascular Scaffolds Thrombosis.

BACKGROUND Everolimus-eluting bioresorbable vascular scaffolds have been developed to improve late outcomes after coronary interventions. However, recent registries raised concerns regarding an increased incidence of scaffold thrombosis (ScT). The mechanism of ScT remains unknown. METHODS AND RESULTS The present study investigated angiographic and optical coherence tomography findings in pati...

متن کامل

Edge Dissections After the Coronary Implantation of Bioresorbable Scaffolds. Serial Analysis Using Optical Coherence Tomography

Background: The incidence of edge dissections after the coronary implantation of bioresorbable scaffolds (BRS) has not been investigated. BRS have thicker struts and require more aggressive pre-dilation for implantation. The incidence of edge dissections after BRS implantation, their morphological aspects and healing process were evaluated using serial optical coherence tomography (OCT) images....

متن کامل

Optical Coherence Tomography and Stent Boost Imaging Guided Bioresorbable Vascular Scaffold Overlapping for Coronary Chronic Total Occlusion Lesion

We report herein the optical coherence tomography (OCT) and stent boost imaging guided bioresorbable vascular scaffold (BVS) implantation for right coronary artery (RCA) chronic total occlusion (CTO) lesion. The gold standard for evaluating BVS expansion after percutaneous coronary intervention is OCT. However, stent boost imaging is a new technique that improves fluoroscopy-based assessments o...

متن کامل

Bioresorbable vascular scaffolds in acute ST-segment elevation myocardial infarction: a prospective multicentre study ‘Prague 19’

AIMS Bioresorbable vascular scaffolds (BVSs) have been studied in chronic coronary artery disease, but not in acute ST-segment elevation myocardial infarction (STEMI). This prospective multicentre study analysed the feasibility and safety of BVS implantation during primary percutaneous coronary intervention (p-PCI) in STEMI. METHODS AND RESULTS Bioresorbable vascular scaffold implantation bec...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European heart journal

دوره 37 26  شماره 

صفحات  -