Increasing the Low-Glucose Alarm of a Continuous Glucose Monitoring System Prevents Exercise-Induced Hypoglycemia Without Triggering Any False Alarms
نویسندگان
چکیده
The use of continuous glucose monitoring systems (CGMSs) with lowglucose alarms is advocated as a means to decrease the risk of hypoglycemia in type 1 diabetes. Unfortunately, marked mismatches between CGMS readings and actual blood glucose (BG) concentrations limit the usefulness of CGMS in preventing hypoglycemia (1). Although we showed recently that raising the alarm level to compensate for this mismatch decreases the incidence and duration of hypoglycemic episodes, this results in an unacceptably high rate of false alarms (1), defined as an alarm triggered when BG levels are greater than the alarm threshold. This is an important issue because repeated exposure to false alarms can discourage individuals from using their CGMSs (2). Given that CGMSs overestimate BG levels when they rapidly decline (3,4), we propose that raising the CGMS alarm in anticipation of a rapid fall in glycemia could be one condition where the incidence of hypoglycemia may be reduced without triggering any false alarms. To test this hypothesis, four males and four females with uncomplicated type 1 diabetes and unimpaired awareness of hypoglycemia (age 31.5 6 6.9 years; BMI 24.8 6 2.5 kg /m; VO2peak 43.2 6 4.9 mL/kg/min; diabetes duration 10.6 6 8.3 years; HbA1c 7.5 6 1.1%; mean 6 SD) wore a CGMS (abdomen; Paradigm 722 Real-Time; Medtronic, Northridge, CA) and attended the laboratory within 1.9 6 0.2 h of breakfast and their usual insulin bolus (8.46 5.1 units). When BG levels fell to between 8–10 mM, participants exercised for 30 min (40% VO2peak) on a cycle ergometer to induce a rapid fall in glycemia (5). During and for 2-h postexercise, the CGMS alarm was either switched off or set to 4.0 or 5.5 mM, with each treatment administered on consecutive mornings following a randomized counterbalanced design. Participants were treated with carbohydrates when an alarm was accompanied by a confirmed BG level # the alarm threshold or in response to the verbal expression of hypoglycemic symptoms. One-way repeatedmeasures ANOVA and Bonferroni post hoc tests compared differences in BG and CGMS levels. Hypoglycemic events were compared using a Fisher exact squared test. In response to exercise, all participants in both the no alarm and 4.0 mM alarm conditions experienced an episode of hypoglycemia, defined as a confirmed BG level,3.8 mM (ABL 700 series; Radiometer, Copenhagen, Denmark), with no cases of false alarms in the 4.0 mM treatment. In comparison, the 5.5 mM alarm significantly reduced byhalf the proportion of hypoglycemic episodes (P5 0.048)with no cases of false alarms. When the 5.5 mM alarm was triggered, CGMS overestimated BG values by 1.6 6 0.3 mM. Our findings show for the first time that when glycemia is falling, the use of CGMS alarms can provide an effective means to reduce the risk of hypoglycemia without the inconvenience of false alarms. Although setting the CGMS alarm at 5.5 mM did not prevent all cases of hypoglycemia because of the large overestimation of BG levels by the CGMS, this mismatch had the benefit of contributing to the absence of false alarms. In conclusion, future diabetes management guidelines should highlight the benefits of using CGMS alarms for the prevention of hypoglycemia when a rapid fall in glycemia is anticipated.
منابع مشابه
Alarm characterization for a continuous glucose monitor that replaces traditional blood glucose monitoring.
BACKGROUND Continuous glucose monitoring (CGM) devices available in the United States are approved for use as adjuncts to self-monitoring of blood glucose (SMBG); all CGM alarms require SMBG confirmation before treatment. In this report, an analysis method is proposed to determine the CGM threshold alarm accuracy required to eliminate SMBG confirmation. METHOD The proposed method builds on th...
متن کاملHypoglycemia prediction with subject-specific recursive time-series models.
BACKGROUND Avoiding hypoglycemia while keeping glucose within the narrow normoglycemic range (70-120 mg/dl) is a major challenge for patients with type 1 diabetes. Continuous glucose monitors can provide hypoglycemic alarms when the measured glucose decreases below a threshold. However, a better approach is to provide an early alarm that predicts a hypoglycemic episode before it occurs, allowin...
متن کاملAccuracy requirements for a hypoglycemia detector: an analytical model to evaluate the effects of bias, precision, and rate of glucose change.
BACKGROUND There has been considerable debate on what constitutes a good hypoglycemia (Hypo) detector and what is the accuracy required from the continuous monitoring sensor to meet the requirements of such a detector. The performance of most continuous monitoring sensors today is characterized by the mean absolute relative difference (MARD), whereas Hypo detectors are characterized by the numb...
متن کاملHypoglycemia detection in critical care using continuous glucose monitors: an in silico proof of concept analysis.
BACKGROUND Tight glycemic control (TGC) in critical care has shown distinct benefits but has also been proven difficult to obtain. The risk of severe hypoglycemia (<40 mg/dl) has been increased significantly in several, but not all, studies, raising significant concerns for safety. Continuous glucose monitors (CGMs) offer frequent measurement and thus the possibility of using them for early det...
متن کاملEditorial: symposium on algorithms for continuous glucose monitoring and control.
1 S YSTEMS AND CONTROL THEORY is the basis for algorithms embedded in many of the products (both high and low " tech ") that we use in our daily lives. While consumers appreciate the relative compactness of CD and DVD players and microdrives, for example, and value the manufacturing technology involved in minia-turization, they probably do not think much about the mathematical algorithms that e...