Spatial characteristics of static and dynamic stereoacuity in strabismus.
نویسندگان
چکیده
The spatial and temporal organization of stereoscopic depth perception were compared in normal and strabismic observers. The minimum and maximum disparities for stimulating static and dynamic stereopsis in strabismus were examined as a function of spatial separation of disparate stimuli. Disparities and their spacing were produced by spatial modulation of two vertical lines viewed haploscopically. Most strabismics had normal upper disparity limits but elevated static and dynamic stereothresholds. Moderate stereothreshold elevations (100 arc sec) were constant for spatial separations greater than 15 arc min. Two new types of spatial crowding effects upon stereopsis were observed. The first type resulted from the constant elevation of the disparity threshold. The second type consisted of a reduced maximum disparity limit for stereopsis. In both cases, the constriction of the range of perceivable depth produced a reduction in the spatial and temporal frequency limits for depth perception. Clinical tests of stereoacuity that crowd stimuli closer than 0.25 degree underestimated the strabismic patients' potential stereoacuities by a factor of 2 to 4. Similarly, tests of dynamic stereopsis that use temporal frequencies greater than 1 Hz will underestimate optimal dynamic stereoacuity.
منابع مشابه
Relationship between Static and Dynamic Balance Characteristics with Types of MS in Women
MS is a lifelong disease that could involve the person in different forms. Knowing balance characteristics of different types of this chronic disease helps the specialists for controlling their complications. The purpose of this study was to recognize static and dynamic balance of different type of MS and to compare MS patients with healthy individual. 54 MS women in three groups (27- Relapsing...
متن کاملBody sway increases immediately after strabismus surgery.
The purposes of this study were to examine whether body sway is altered immediately after strabismus surgery in children and to find preoperative clinical factors associated with body sway. In a prospective study, body sway was measured on 1-3 days before surgery and on the third day after surgery; for the measurements, computerized static stabilometry was carried out on 28 consecutive patients...
متن کاملFactors influencing stereoacuity levels after surgery to correct unilateral developmental cataracts in children.
AIM To evaluate factors influencing stereoacuity after surgery to correct unilateral developmental pediatric cataracts. METHODS We retrospectively surveyed 110 patients who had undergone removal of unilateral acquired developmental cataracts and primary posterior chamber intraocular lens implantation between February 1992 and December 2009. In all patients, stereoacuity was assessed using the...
متن کاملCorrelation between Depth Perception by Three-Rods Test and Stereoacuity by Distance Randot Stereotest
BACKGROUND The examination of depth perception with three-rods test, in addition to visual acuity testing, is required to obtain motor vehicle license to drive taxies and trucks, according to the Road Traffic Act in Japan. The aim of this study was to examine whether the results of the three-rods test would correlate with the results of static stereopsis tests, used in ophthalmic practice. ME...
متن کاملA COMPARATIVE STUDY ON CHARACTERISTICS OF DYNAMIC OXIDE FILM OF MOLTEN Zn-Al ALLOYS
This paper investigates the difference between thickness of zinc-based alloys oxide films in dynamic condition using the oxide-metal-oxide (OMO) sandwich method and static condition by theoretical calculations. In dynamic condition, the thickness of the oxide film in the OMO sandwich sample was characterized by scanning electron microscopy (SEM). In the static condition, the thickness and type ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 24 12 شماره
صفحات -
تاریخ انتشار 1983