Regional pressure and temperature variations across the injured human brain: comparisons between paired intraparenchymal and ventricular measurements
نویسندگان
چکیده
INTRODUCTION Intraparenchymal, multimodality sensors are commonly used in the management of patients with severe traumatic brain injury (TBI). The 'gold standard', based on accuracy, reliability and cost for intracranial pressure (ICP) monitoring is within the cerebral ventricle (external strain gauge). There are no standards yet for intracerebral temperature monitoring and little is known of temperature differences between brain tissue and ventricle. The aim of the study therefore was to determine pressure and temperature differences at intraparenchymal and ventricular sites during five days of continuous neuromonitoring. METHODS Patients with severe TBI requiring emergency surgery. INCLUSION CRITERIA patients who required ICP monitoring were eligible for recruitment. Two intracerebral probe types were used: a) intraventricular, dual parameter sensor (measuring pressure, temperature) with inbuilt catheter for CSF drainage: b) multiparameter intraparenchymal sensor measuring pressure, temperature and oxygen partial pressure. All sensors were inserted during surgery and under aseptic conditions. RESULTS Seventeen patients, 12 undergoing neurosurgery (decompressive craniectomy n = 8, craniotomy n = 4) aged 21-78 years were studied. Agreement of measures for 9540 brain tissue-ventricular temperature 'pairs' and 10,291 brain tissue-ventricular pressure 'pairs' were determined using mixed model to compare mean temperature and pressure for longitudinal data. There was no significant overall difference for mean temperature (p = 0.92) or mean pressure readings (p = 0.379) between tissue and ventricular sites. With 95.8 % of paired temperature readings within 2SD (-0.4 to 0.4 °C) differences in temperature between brain tissue and ventricle were clinically insignificant. For pressure, 93.5 % of readings pairs fell within the 2SD range (-9.4756 to 7.8112 mmHg). However, for individual patients, agreement for mean tissue-ventricular pressure differences was poor on occasions. CONCLUSIONS There is good overall agreement between paired temperature measurements obtained from deep white matter and brain ventricle in patients with and without early neurosurgery. For paired ICP measurements, 93.5 % of readings were within 2SD of mean difference. Whilst the majority of paired readings were comparable (within 10 mmHg) clinically relevant tissue-ventricular dissociations were noted. Further work is required to unravel the events responsible for short intervals of pressure dissociation before tissue pressure readings can be definitively accepted as a reliable surrogate for ventricular pressure.
منابع مشابه
Evaluation of Morphometric Differences among Indigenous Chicken Populations in Bale Zone, Oromia Regional State, Ethiopia
The study was conducted in five selected districts in Bale zone South East, Ethiopia to evaluate the morphometric difference among indigenous chicken populations. Simple random sampling method was used to select 400 households who owned indigenous chicken population. From these households, a total of 840 adult (more than 6 months of age) indigenous chickens (225 males and 615 females) were used...
متن کاملTemperature, Salinity and Density Measurements in the Coastal Waters of the Rudsar, South Caspian Sea
CTD (conductivity, temperature and depth) data collected in the coastal waters of Rudsar in summer 2008 were analyzed to identify the isothermal layers, thermocline depth and vertical structure of seawater properties. During the survey, probe was released into the seawater column down to 117 m depth. Results showed a vertical variation of temperature between 29°C at the sea surface and less tha...
متن کاملFrontal intraparenchymal schwannoma: a case report
Abstract The Intraparenchymal schwannomas are very rare tumors with only 52 reported cases . We describe a 38 years old man with eight months history of poorly controlled seizures despite of medical therapy. On brain CT scan a 1.5 x 1.5 cm hypodense enhancing lesion was seen in right posterior-inferior frontal lobe. On brain MRI the lesion was hypointense in T1 and hyperintense in T...
متن کاملCerebrospinal Pulsation Hydrodynamics in a 2D Simulation of Brain Ventricles
In this article, dynamics of the cerebrospinal fluid (CSF) was studied, using computational fluid dynamics. Using MRI images of two special cases, a 2-dimensional model of the ventricular system was made. CSF velocity and pressure distribution in ventricular system have high importance since the flow pattern of this liquid has an important effect on intracranial pressure, i.e., ICP, which has a...
متن کاملNoninvasive detection of alarming intracranial pressure changes by auditory monitoring in early management of brain injury: a prospective invasive versus noninvasive study
BACKGROUND In brain-injured patients intracranial pressure (ICP) is monitored invasively by a ventricular or intraparenchymal transducer. The procedure requires specific expertise and exposes the patient to complications such as malposition, hemorrhage or infection. As inner-ear fluid compartments are connected to the cerebrospinal fluid space, ICP changes elicit subtle changes in the physiolog...
متن کامل