Biventricular assist devices as a bridge to heart transplantation in small children.
نویسندگان
چکیده
BACKGROUND Experience with the use of biventricular assist device (BiVAD) support to bridge small children to heart transplantation is limited. METHODS AND RESULTS We used BIVAD support (Berlin EXCOR) in 9 pediatric heart transplant candidates from 4/05 to 7/07. The median patient age was 1.7 years (12 days to 17 years). The median patient weight was 9.4 kg (3 to 38 kg). All children were supported with multiple intravenous inotropes+/-mechanical ventilation (6) or ECMO (3) before BiVAD implantation. All had significant right ventricular dysfunction. The median pulmonary vascular resistance index (Rpi) was 6.0 WU/m(2). Eight patients were successfully bridged to heart transplantation after a median duration of BiVAD support of 35 days (1 to 77 days). One death occurred after 10 days of support from perioperative renal failure in a 3 kg infant. Five patients required at least 1 blood pump change. One patient had a driveline infection requiring treatment. There were no acute neurological complications, no thromboembolic events, and no bleeding complications. In 2 patients with Rpi >10 WU/m(2) unresponsive to pulmonary vasodilator therapy, Rpi dropped to 1.4 and 4.6 WU/m(2), after 33 and 41 days of support, respectively. All 8 survivors underwent successful heart transplantation. Of 5 patients supported >30 days, 3 developed an extremely elevated (>90%) panel reactive antibody by ELISA that was not confirmed by other methods; none had a positive donor-specific retrospective crossmatch. There was 1 episode of rejection (with hemodynamic compromise) in the 8 transplanted patients. Rpi was normal (<3 WU/m(2)) without pulmonary vasodilators in all patients within 3 months after transplant. There have been no deaths after transplant with a median follow-up of 19 months. CONCLUSIONS BiVAD support can effectively be used in small children as a bridge to heart transplantation and can be accomplished with low mortality and morbidity. BiVAD support may offer an additional means to reverse extremely elevated pulmonary vascular resistance. Surveillance for HLA antibody sensitization during BiVAD support may be complicated by the development of non-HLA antibodies which may not reflect true HLA presensitization.
منابع مشابه
Laparoscopic Cholecystectomy in a Patient With a Biventricular Cardiac Assist Device
Evaluation and management of abdominal pathology in patients with ventricular assist devices is likely to become increasingly important as the utilization of these devices expands. Ventricular assist devices represent a class of intracorporeal or paracorporeal mechanical devices that augment cardiac output in patients with congestive heart failure. Patients with ventricular assist devices suppo...
متن کاملOutcomes of children bridged to heart transplantation with ventricular assist devices: a multi-institutional study.
BACKGROUND Current ventricular assist devices (VADs) in the United States are designed primarily for adult use. Data on VADs as a bridge to transplantation in children are limited. METHODS AND RESULTS A multi-institutional, prospectively maintained database of outcomes in children after listing for heart transplantation (n=2375) was used to analyze outcomes of VAD patients (n=99, 4%) listed b...
متن کاملCirculatory support with paracorporeal pneumatic ventricular assist device (VAD) in infants and children.
OBJECTIVE The feasibility and efficacy of the pneumatic 'Berlin Heart' ventricular assist device (VAD) were evaluated in 14 pediatric patients with profound cardiogenic shock refractory to conventional therapy. METHODS There were two patient groups. Eleven patients, aged 2 weeks 15 years and weighing 3.2-52 kg received a left ventricular assist device or a biventricular assist device as a bri...
متن کاملLetter by Singh Regarding Article, "Berlin Heart EXCOR pediatric ventricular assist device for bridge to heart transplantation in US children".
BACKGROUND Recent data suggest that the Berlin Heart EXCOR Pediatric ventricular assist device is superior to extracorporeal membrane oxygenation for bridge to heart transplantation. Published data are limited to 1 in 4 children who received the device as part of the US clinical trial. We analyzed outcomes for all US children who received the EXCOR to characterize device outcomes in an unselect...
متن کاملCASE STUDY Children may survive severe myocarditis with prolonged use of biventricular assist devices
The outcome of acute myocarditis with cardiogenic shock is poor. In some children in whom aggressive medical treatment fails, artificial replacement of heart function may oVer lifesaving support until the myocardium has recovered. Four previously healthy children (three boys aged 4, 6, and 1 years; one girl aged 5) developed acute myocarditis with ventricular failure and multiorgan dysfunction ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 118 14 Suppl شماره
صفحات -
تاریخ انتشار 2008