MATRIX-INDEPENDENT XRF METHODS FOR CERTIFICATION OF STANDARD REFERENCE MATERIALS, J.R. Sieber, pp. 493-504

نویسنده

  • John R. Sieber
چکیده

The Spectrochemical Methods Group of the Analytical Chemistry Division at the National Institute of Standards and Technology develops and applies matrix-independent methods for its certification of Standard Reference Materials (SRM). Such methods are required to achieve accuracy, i.e., to minimize potential sources of analytical uncertainty. This paper delineates a matrix-independent method for X-ray fluorescence spectrometry that uses destructive sample preparation instead of matrix corrections. The method is based on borate fusion of samples and synthesis of calibration standards that closely mimic the complete composition of the fused samples. The method is described in detail and illustrated using recent work on cements and zeolites. A typical uncertainty budget is itemized and sources of uncertainty are discussed. Expanded relative uncertainties are 1 % or lower. The technique is applicable to major, minor and sometimes trace constituents. Excellent agreement is demonstrated with both a classical gravimetric method and instrumental neutron activation analysis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Major- and Trace-element Analysis of Sulfide Ores by Laser-ablation Icp–ms, Solution Icp–ms, and Xrf: New Data on International Reference Materials

International reference materials representing a diverse suite of sulfide ores and related lithologies have been analyzed for major and trace element concentrations by XRF, solution ICP–MS, and laser-ablation ICP–MS (LA–ICP–MS) after fusion of the sample to a lithium borate glass. Reference materials analyzed for this study include a wide variety of bulk compositions, including ores of Pb–Zn su...

متن کامل

A new river sediment standard reference material.

The collection, processing and certification of a new sediment Standard Reference Material (SRM), SRM 2704, is described. Collected from the bottom of the Buffalo River in New York State during the fall of 1986, SRM 2704 is certified for 25 elements with information provided on another 22 elements. Improvements in analytical methods as well as the application of well-defined quality-control pro...

متن کامل

RESEARCH IN QUANTITATIVE X-RAY FLUORESCENCE MICROANALYSIS OF PATTERNED THIN FILMS, M. Lankosz, J.R. Sieber and J. Pedulla, pp. 497-503

The applicability of micro X-ray fluorescence (MXRF) for analysis of thin films was investigated. For the restoration of a microbeam profile of primary X-rays from a wire scan, a mathematical procedure was developed. In order to verify obtained results, a CCD camera was used for direct measurements of beam profiles. Reasonably good agreement was obtained between results of measurements and calc...

متن کامل

Determining the Content of Silicon Dioxide in Bauxites Using X-Ray Fluorescence Spectrometry

The X-ray fluorescence spectrometry and the MA.BM.006 reference spectrophotometric methods were used to determine the content of SiO2 (%) in bauxites from different deposits. The treatment of samples prior to the analysis involved the following steps: annealing, melting using the borax method,  and the formation of beads. Certified reference bauxite samples were used for the cali...

متن کامل

Determination of Trace Level Iodine in Biological and Botanical Reference Materials by Isotope Dilution Mass Spectrometry

A method has been developed for the determination of trace level iodine in biological and botanical materials. The method consists of spiking a sample with 129I, equilibration of the spike with the natural iodine, wet ashing under carefully controlled conditions, and separation of the iodine by co-precipitation with silver chloride. Measurement of the 129I/127I ratio is accomplished by negative...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002