Ultrasound Evaluation of the Transverse Movement of the Flexor Pollicis Longus Tendon on the Distal Radius during Wrist and Finger Motion in Healthy Volunteers.

نویسندگان

  • Mitsuhiko Nanno
  • Takuya Sawaizumi
  • Norie Kodera
  • Yuji Tomori
  • Shinro Takai
چکیده

PURPOSE This study aimed to evaluate the kinematics of the flexor pollicis longus tendon (FPL) at the wrist by examining the movement of the FPL on the distal radius during various wrist and finger motions using transverse ultrasound in healthy volunteers. METHODS Forty-eight wrists of 24 asymptomatic volunteers were examined by transverse ultrasound to observe the location of the FPL on the distal radius at 5 wrist positions (neutral, 60° dorsal flexion, 60° palmar flexion, 40° ulnar deviation, and 10° radial deviation) with all 5 fingers in full extension and full flexion, and isolated thumb in full flexion, respectively. RESULTS We found that the FPL was situated statistically significantly more ulnodorsally at the wrist dorsal and ulnar deviation positions, more ulnopalmarly at the wrist palmar flexion position, and more radiopalmarly at the wrist radial deviation-position than at the wrist neutral position with all 5 fingers at full extension. Especially, it moved statistically significantly most ulnodorsally at the wrist dorsal flexion position during finger motion. The FPL moved most statistically significantly ulnopalmarly at the wrist palmar flexion position with all 5 fingers in full extension among all wrist positions during finger motion. During finger motion, the wrist dorsal flexion position induced significant displacement of the FPL to the distal radius and compressed it between the flexor tendons and the distal radius. The average distance between the FPL and the volar surface of the distal radius in the palmar-dorsal direction at wrist dorsal flexion position in all fingers at full flexion was 1.9 mm, the smallest among all wrist positions during finger motion. CONCLUSIONS There is a significant relationship between the transverse movement of the FPL at the distal radius and wrist and finger motions. Our findings indicated that the irritation of the FPL caused by the movement of both the FPL itself and of the flexor digitorum superficialis and profundus is most induced with the wrist in dorsal flexion with all 5 fingers at full flexion compared to other wrist positions during finger motion. This wrist position might be the optimum one at which to evaluate the irritation of the FPL from volar locking plates in patients with distal radius fracture. We believe that our transverse ultrasound results can play a role in the gaining of a better understanding of the kinematics of the FPL. Moreover, they have potential to lead to improved diagnosis of and treatment for fractures of the distal radius and help to minimize the risk of FPL rupture related to volar locking plates.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transverse Plane Tendon and Median Nerve Motion in the Carpal Tunnel: Ultrasound Comparison of Carpal Tunnel Syndrome Patients and Healthy Volunteers

BACKGROUND The median nerve and flexor tendons are known to translate transversely in the carpal tunnel. The purpose of this study was to investigate these motions in differential finger motion using ultrasound, and to compare them in healthy people and carpal tunnel syndrome patients. METHODS Transverse ultrasounds clips were taken during fist, index finger, middle finger and thumb flexion i...

متن کامل

Flexor pollicis longus dysfunction after volar plate fixation of distal radius fractures.

PURPOSE To evaluate the natural history and etiology of decreased thumb interphalangeal (IP) joint flexion after volar plate fixation of distal radius fractures. METHODS A total of 46 patients who underwent volar plating of 48 distal radius fractures by a single surgeon were retrospectively studied. Of those patients, 24 (24 wrists) exhibited loss of thumb IP joint flexion (group 1) and 22 (2...

متن کامل

Ultrasonographic Assessment of the Flexor Pollicis Longus Tendon After Plate Fixation.

Rupture of the flexor pollicis longus tendon is a major complication after volar locking plate fixation of distal radius fracture. This study used ultrasonography to assess the flexor pollicis longus tendon and intermediate tissue. The study assessed 27 patients (28 wrists) who underwent removal of the volar locking plate. Before plate removal, radiography and ultrasonography were performed to ...

متن کامل

Transverse Ultrasound Assessment of the Displacement of the Median Nerve in the Carpal Tunnel during Wrist and Finger Motion in Healthy Volunteers.

PURPOSE The purpose of this study was to investigate the displacement of the median nerve in the carpal tunnel during finger motion at varied wrist positions using transverse ultrasound in healthy volunteers, in order to clarify the appropriate position of a wrist splint in treating carpal tunnel syndrome. METHODS Fifty wrists of 25 asymptomatic volunteers were evaluated by transverse ultraso...

متن کامل

گزارش یک مورد نادر آسیب بسته تاندون‌های فلکسور عمقی

     Introduction: The usual causes of flexor tendon injuries in hand are penetrating wounds. Closed injury and avulsion of flexor tendon are rare and mostly occur as avulsion of flexor digitorum profundus tendon of ring finger from its bony insertion at distal phalanx. Closed avulsion of flexor digitorum superficialis is even rarer. The rarest is simultaneous closed avulsion of both flexors in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of Nippon Medical School = Nippon Ika Daigaku zasshi

دوره 82 5  شماره 

صفحات  -

تاریخ انتشار 2015